Select your location

Fire detection systems
UL 4-Way conventional device controller for addressable fire systems
Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

UL 4-Way conventional device controller for addressable fire systems

The UL listed fire alarm sounder control unit connects a zone of suitable conventional detectors and a separate zone of conventional callpoints (if required) to an addressable panel. It allows for easier connection to existing conventional detection zones, as long the devices used are compatible.

The unit only uses a single address yet each circuit can be independently controlled according to the required cause and effect programming. 

Convenient for smaller commercial builds, the UL 4 Way Sounder Controller Unit provides an ideal addition to Eaton’s UL ceiling and wall horns/strobes.

Eaton UL 4 Way Device Controller Unit
Plug and play
No hard addressing required
Dependable
24 hour integral battery back-up
Effective
4 separate sounder circuit outputs

Build on your existing addressable fire alarm system

Eaton's 4-way sounder controller unit is predominately designed for building on your existing Eaton addressable fire alarm system. 

The unit is ideal for use when buildings are extended and when users need to expand their addressable fire alarm systems. Perfect for use in schools, offices and apartment complexes.

Tailor your fire system to match project needs

An extensive range of interfaces are available to support Eaton's range of UL listed fire system control panels, providing solutions for most design requirements. These include interfaces for system extension and retrofitting, and ones to incorporate into external equipment such as generators and HVAC. The range will help you tailor your fire system to your exact requirements.

Ensuring a consistent performance with a built-in back up battery

The unit is designed to continue to provide an impressive performance even under mains failure conditions, with an incorporated back up battery to maintain functionality.

Maintain efficiency with independent output control

The outputs of the 4 way controller are independently controlled, meaning delays with 1 circuit will not affect other circuits. There is no need for the unit to wire conventional sounders back to the control panel, instead the beacons and strobes can be wired directly to the interface saving on both time and installation costs.

Eaton UL listed fire systems, setting projects apart from the rest

Since the launch of Eaton's UL Listed fire product range, several prestigious projects worldwide have been supplied with products including the Hyatt Resort and Spa, Shangri-La at the Fort and Times Square projects in South East Asia and several major projects in the Middle East, including within the Riyadh Financial district.