Wählen Sie bitte Ihren Standort

Eaton Intelligent Power Manager
Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.
Spezifikationen

Zusammenhängende Darstellung von Leistungsmetriken & Beschränkungen

  Understand Manage Optimize
Dashboard view
Data center view
Rack view
Environmental view
Asset management

Überwachung von Eaton Geräten & von vielen Drittanbieter-Geräten

  Understand Manage Optimize
Eaton UPSs, rack PDUs & ATSs
3rd party UPSs, rack PDUs & ATSs 1 2 2

Manage & update Eaton Power Devices

  Understand Manage Optimize
Mass configure Eaton power devices
Mass upgrade Eaton power devices

Standardmäßige Power Management Funktionen

  Understand Manage Optimize
Protected Servers (via IPP agent) and Virtual Hosts (agentless)
Storage Shutdown Module
Generic Drivers and Third Party Devices
Configuration Policy
Control PDU outlets
Advanced Event Action with Standard Events
Advanced Event Action with Custom Events
Generic SSH action

Definition grundlegender virtueller Infrastruktur Richtlinien zur Geschäftskontinuität mit Maßnahmen auf Host-Ebene

  Understand Manage Optimize
Basic Power Actions
Shutdown Storage Devices 3
Shutdown Virtual Hosts 3

Shutdown Virtual Machines

(all, no prioritization in IPM policy)

3
Enter/Exit Maintenance Mode 3

Definition erweiterter virtueller Infrastruktur Richtlinien zur Geschäftskontinuität mit Maßnahmen auf VM & Cluster-Ebene

Includes all basic power actions listed table above plus the following
  Understand Manage Optimize
Advanced Power Actions for VM/Volume
Load shedding
Shutdown Targeted Virtual Machines
Migrate Virtual Machines to Targeted Hosts
Automatic VM group assignment
Advanced Power Actions for Hosts
Shutdown VMware vApp
Automate VMware SRM Recovery Plan
Virtual IT Cluster Level
Fully virtualized cluster shutdown
VMware vSAN shutdown
Nutanix Acropolis shutdown

Plugins & Adapter für IT-Lösungen von Drittanbietern

  Understand Manage Optimize
Virtualisation management plugins
Plugin for VMware vCenter 3
Plugin for Citrix XenCenter 3
Advanced Power Actions for Hosts
Shutdown VMware vApp 3
Automate VMware SRM Recovery Plan 3
Microsoft Hyper-V 3
Citrix XenCenter 3
Citrix XenServer Pool 3
NetApp Storage 3
OpenStack
HPE OneView
Nutanix Acropolis
Cisco UCS Manager
Management Packs

Eaton IPM Management Pack

for VMware vRealize Operations Manager

Legende
 
 
 
✔1 Fehlende Gerätetreiber für unterstützte Gerätetypen von Drittanbietern können vom Eaton Support in der Regel innerhalb von 72 Stunden bereitgestellt werden. Es gelten jedoch einige Einschränkungen.
 
✔2 Richtlinienbasierte Abhilfemaßnahmen auf Host-Ebene sind für Eaton Essential USV-Modelle (9E und 93E) und alle USV-Modelle von Drittanbietern in der Manage Edition nicht enthalten.
Die Optimize Edition ist hierfür erforderlich.
Funktionen zur USV-Überwachung & zur Durchsetzung von Richtlinien zur Geschäftskontinuität von Drittanbietern erfordern eine Geräteunterstützung für den IETF MIB RFC 1628.
 
✔3 USV-Kunden von Drittanbietern müssen eine Optimize Edition-Lizenz erwerben, um grundlegende und erweiterte Virtualisierungsfunktionen freizuschalten.