Wählen Sie bitte Ihren Standort

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.
Spezifikationen

Allgemeine spezifikation

Product Name
Eaton Ellipse ECO UPS
Catalog Number
EL650DIN
Product Length/Depth
81 MM
Product Height
263 MM
Product Width
235 MM
Product Weight
3.6 KG
Warranty
2 year
Compliances
CE Marked
Certifications
IEC/EN 62040-1
IEC/EN 62040-2
CE
EAC

Produktspezifikationen

Secondary frequency - max
60 HZ
Wattage
400W
Output power factor
0.6
Form factor
Rack/tower
Includes network card
No
Input connection
Protective contact (SCHUKO)
Input voltage - min
161 V
Output voltage - max
284 V
Secondary frequency - min
50 HZ
Battery replacement
User replaceable
Battery type
Sealed, lead-acid
Efficiency
98
Number of outputs hardwired
0
Special features
Convenient extra-flat design for easy installation in any office environment.
High performance surge-protection device compliant with IEC 61643-11 standard.
Data line protection to ensure that the internet line (including xDSL) is protected against surges.
4 outlets to connect your PC + peripherals.
Easy to replace battery helps to extend UPS service life.
Construction type
Free standing model
Output voltage - min
161 V
Color
Black
Output voltage range
184-264V (adjustable to 161-284V)
Extended battery capability
No
Topology
Offline
Surge protection
Yes
Back-up time
2 min
Input nominal voltage
230V default (220/230/240V)
Input frequency range
46-70 Hz
Input voltage - max
284 V
Voltage type
AC
Phase (output)
1
Battery management
Replaceable batteries, Automatic battery test, deep-discharge protection, cold-start capable
Auto shutdown function
No
Number of Outputs C13
0
Number of Outputs C19
0
Operating temperature - min
0 C
VA rating
650 VA
Potential free switch contact
No
Receptacle
(3) Schuko, (1) Schuko surge only
Phase (input)
1
Package contents
Power cord.
User manual in 20 languages.
Safety Instructions.
Noise level
<25 dB at 1 meter
Feed type
1
Runtime graph
View runtime graph
User interface
LEDs
Battery quantity
1
Operating temperature - max
35 C
Voltage
230V
Input cord length
1.5 m
Temperature range
0° to 35°C (32° to 95°F)
Ethernet interface
No
Relative humidity
0-85% non-condensing
Output apparent power
650 VA
Rack mounting kit
No
Num of Outputs PC (SCHUKO)
4
Output frequency
50-60 Hz
Runtime at full load
2 min
Type of interface
None
Primary frequency - min
46 HZ
Battery rating
12V / 7Ah
Type
UPS
Output nominal voltage
230V default (220/230/240V)
Expansion slots
No
Input voltage range
184-264V (adjustable to 161-284V)
Nominal frequency
50/60 Hz
Primary frequency - max
70 HZ
Altitude
2000 m