Reset
Eaton Moeller series NZM - Molded Case Circuit Breaker. Molded Case Switch, 3p, 200A
| Product Name |
Eaton Moeller series NZM molded case switch
|
| Catalog Number |
102685
|
| Model Code |
NS2-200-NA
|
| EAN |
4015081025459
|
| Product Length/Depth |
142 mm
|
| Product Height |
185 mm
|
| Product Width |
105 mm
|
| Product Weight |
2.423 kg
|
| Compliances |
RoHS conform
|
| Certifications |
CSA (File No. 22086)
UL/CSA IEC CSA (Class No. 4652-06) UL (File No. E148671) UL 489 Specially designed for North America UL listed CSA-C22.2 No. 5-09 IEC 60947-2 CE marking UL (Category Control Number WJAZ) CSA certified |
| Voltage rating |
690 V - 690 V
|
| Rated operating voltage Ue (UL) - max |
600 Y / 347 V
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Current rating (Iu) (UL 489 csa 22.2 no. 5.1) |
250 A
|
| Rated current (Iu) |
250 A
|
| Amperage Rating |
200 A
|
| Instantaneous current setting (Ii) - min |
2500 A
|
| Instantaneous current setting (Ii) - max |
2500 A
|
| Short-circuit release non-delayed setting - min |
2500 A
|
| Short-circuit release non-delayed setting - max |
2500 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
130 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
37.5 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
5 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
286 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
53 kA
|
| Short-circuit total breaktime |
< 10 ms
|
| Electrical connection type of main circuit |
Screw connection
|
| Number of operations per hour - max |
120
|
| Handle type |
Rocker lever
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
10000 operations at 400 V AC-1
6500 operations at 400 V AC-3 10000 operations at 415 V AC-1 6500 operations at 415 V AC-3 5000 operations at 690 V AC-3 7500 operations at 690 V AC-1 |
| Direction of incoming supply |
As required
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Current rating (Iu) (UL 489 csa 22.2 no. 5.1) |
250 A
|
| Rated current (Iu) |
250 A
|
| Amperage Rating |
200 A
|
| Instantaneous current setting (Ii) - min |
2500 A
|
| Instantaneous current setting (Ii) - max |
2500 A
|
| Short-circuit release non-delayed setting - min |
2500 A
|
| Short-circuit release non-delayed setting - max |
2500 A
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
150 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
130 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz |
37.5 kA
|
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz |
5 kA
|
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz |
330 kA
|
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz |
286 kA
|
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz |
105 kA
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
53 kA
|
| Short-circuit total breaktime |
< 10 ms
|
| Electrical connection type of main circuit |
Screw connection
|
| Number of operations per hour - max |
120
|
| Handle type |
Rocker lever
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Lifespan, electrical |
10000 operations at 400 V AC-1
6500 operations at 400 V AC-3 10000 operations at 415 V AC-1 6500 operations at 415 V AC-3 5000 operations at 690 V AC-3 7500 operations at 690 V AC-1 |
| Direction of incoming supply |
As required
|
| Mounting Method |
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional Fixed |
| Degree of protection |
IP20
In the area of the HMI devices: IP20 (basic protection type) |
| Degree of protection (IP), front side |
IP40 (with insulating surround)
IP66 (with door coupling rotary handle) |
| Degree of protection (terminations) |
IP00 (terminations, phase isolator and band terminal)
IP10 (tunnel terminal) |
| Number of auxiliary contacts (change-over contacts) |
0
|
| Number of auxiliary contacts (normally closed contacts) |
0
|
| Number of auxiliary contacts (normally open contacts) |
0
|
| Position of connection for main current circuit |
Front side
|
| Switch positions |
I, +, 0
|
| Lifespan, mechanical |
20000 operations
|