Eaton DG1 Variable frequency drive, 240 V AC, 3-phase, 25 A/5.5 kW/7.5 HP, IP21, NEMA 1, FS2, Radio interference, Brake chopper
| Product Name |
Eaton DG1 variable frequency drive
|
| Catalog Number |
9701-2001-00P
|
| EAN |
4015081734078
|
| Product Length/Depth |
244.7 mm
|
| Product Height |
419 mm
|
| Product Width |
167.8 mm
|
| Product Weight |
10.2 kg
|
| Certifications |
Safety requirements: IEC/EN 61800-5
CSA-C22.2 No. 274-13 UL Category Control No.: NMMS, NMMS7 UL CE UL report applies to both US and Canada IEC/EN 61800-3 Certified by UL for use in Canada RoHS, ISO 9001 C-Tick UkrSEPRO IEC/EN61800-3 Specification for general requirements: IEC/EN 61800-2 IEC/EN61800-5 CUL EAC UL508 UL File No.: E134360 |
| Catalog Notes |
The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
|
| Model Code |
DG1-32025FB-C21C
|
| Apparent power at 230 V |
12.3 kVA
|
| Apparent power at 240 V |
12.9 kVA
|
| Braking resistance |
20 Ω
|
| Braking torque |
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit Adjustable to 150 % (I/Ie), DC - Main circuit Max. 100 % of rated operational current Ie with external braking resistor - Main circuit |
| Switch-on threshold for the braking transistor |
425 VDC
|
| Altitude |
Max. 1000 m
Max. 2000 m for Corner Grounded TN Systems Max. 3000 m Above 1000 m with 1 % derating per 100 m |
| Ambient operating temperature - max |
50 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient operating temperature - min |
-10 °C
|
| Ambient operating temperature at 150% overload - max |
50 °C
|
| Ambient operating temperature at 150% overload - min |
-30 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
| Communication interface |
Modbus RTU, built in
PROFIBUS, optional SmartWire-DT, optional Modbus TCP, built in CANopen®, optional DeviceNet, optional BACnet MS/TP, built in Ethernet IP, built in |
| Connection to SmartWire-DT |
In conjunction with DXG-NET-SWD SmartWire DT module
Yes |
| Protocol |
CAN
TCP/IP BACnet Other bus systems MODBUS DeviceNet PROFIBUS PROFINET IO EtherNet/IP |
| Number of inputs (analog) |
2
|
| Number of inputs (digital) |
8
|
| Number of outputs (analog) |
2
|
| Number of outputs (digital) |
1
|
| Number of relay outputs |
3 (parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 V AC) / 6 A (24 V DC))
|
| Rated control voltage (Uc) |
24 V DC (external, max. 250 mA options incl.)
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Equipment heat dissipation, current-dependent Pvid |
315 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation details |
Operation (with 150 % overload), allow for derating
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Rated operational current for specified heat dissipation (In) |
25 A
|
| Static heat dissipation, non-current-dependent Pvs |
16.62 W
|
| Features |
Temperature-controlled fan
Tool-less swapping of fan Parameterization: Fieldbus Parameterization: Keypad Parameterization: Power Xpert inControl |
| Functions |
4-quadrant operation possible
|
| Air volume capacity |
94 m³/h
|
| Cable length |
C2 ≤ 10 m, Radio interference level, maximum motor cable length
150 m, screened, maximum permissible, Motor feeder C3 ≤ 50 m, Radio interference level, maximum motor cable length |
| Degree of protection |
IP21
NEMA 1 |
| Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
| Environmental class |
3C2, 3S2 (Air quality)
|
| Fitted with: |
Radio interference suppression filter
DC link choke Multi-line graphic display Breaking resistance Brake chopper Additional PCB protection PC connection Control unit Internal DC link IGBT inverter |
| Mounting position |
Vertical
|
| Number of slots |
2 (expansion)
|
| Overvoltage category |
III
|
| Pollution degree |
2
|
| Product Category |
Variable frequency drives
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
| Radio interference class |
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments C1: with external filter, for conducted emissions only |
| Safety function/level |
STO (Safe Torque Off, SIL1, PLc Cat 1)
|
| Shock resistance |
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) UPS drop test (for weights inside the UPS frame) |
| Suitable for |
Branch circuits, (UL/CSA)
|
| Vibration |
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak) Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6 |
| Frame size |
FS2
|
| Current limitation |
0.1 - 2 x IH (CT), motor, main circuit
|
| Efficiency |
97.4 % (η)
|
| Heat dissipation at current/speed |
104 W at 25% current and 50% speed
125 W at 100% current and 50% speed 131 W at 100% current and 0% speed 148 W at 50% current and 50% speed 158 W at 50% current and 90% speed 267 W at 50% current and 0% speed 291 W at 100% current and 90% speed 86 W at 25% current and 0% speed |
| Input current ILN at 110% overload |
29 A
|
| Input current ILN at 150% overload |
23.1 A
|
| Leakage current at ground IPE - max |
6 mA
|
| Mains current distortion |
33.3 %
|
| Mains switch-on frequency |
Maximum of one time every 60 seconds
|
| Mains voltage - max |
240 V
|
| Mains voltage - min |
200 V
|
| Mains voltage tolerance |
200 - 240 V (-15 %/+10 %, at 50/60 Hz)
|
| Operating mode |
U/f control
Sensorless vector control (SLV) Torque regulation Speed control with slip compensation |
| Output frequency - max |
400 Hz
|
| Output frequency - min |
0 Hz
|
| Output voltage (U2) |
230 V AC, 3-phase
240 V AC, 3-phase |
| Overload current IL at 110% overload |
34.1 A
|
| Overload current IL at 150% overload |
37.5 A
|
| Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
| Rated frequency - max |
66 Hz
|
| Rated frequency - min |
45 Hz
|
| Rated operational current (Ie) at 110% overload |
31 A
|
| Rated operational current (Ie) at 150% overload |
25 A
|
| Rated operational power at 220/230 V, 50 Hz, 3-phase, 110% overload |
7.5 kW
|
| Rated operational voltage |
230 V AC, 3-phase
240 V AC, 3-phase |
| Resolution |
0.01 Hz (Frequency resolution, setpoint value)
|
| Short-circuit protection rating |
35 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
| Starting current - max |
200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section
|
| Supply frequency |
50/60 Hz
|
| Switching frequency |
4 kHz, 1 - 12 kHz adjustable, fPWM, Power section, Main circuit
|
| System configuration type |
TN-S, TN-C, TN-C-S, TT, IT
|
| Voltage rating - max |
240 VAC
|
| Rated conditional short-circuit current (Iq) |
100 kA
|
| Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload |
22 A
|
| Assigned motor current IM at 230 V, 50 Hz, 110% overload |
26.4 A
|
| Assigned motor current IM at 230 V, 50 Hz, 150% overload |
19.6 A
|
| Assigned motor current IM at 230 V, 60 Hz, 110% overload |
28 A
|
| Assigned motor power at 230/240 V, 60 Hz, 3-phase, 110 % overload |
10 HP
|