TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9
| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SM2200RMXL2UTAA
|
| UPC |
037332152800
|
| Product Length/Depth |
20.9 in
|
| Product Height |
8.8 in
|
| Product Width |
24 in
|
| Product Weight |
57.6 lb
|
| Compliances |
RoHS
FCC Class A TAA Compliant |
| Certifications |
CSA certified
NOM UL 1778 |
| Topology |
Line-interactive
|
| Form factor |
Rackmount
|
| Rack size |
2U
|
| Package contents |
|
| Input nominal voltage |
120 VAC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
16A (120V)
|
| Battery replacement |
RBC94-2U
|
| Runtime at half load |
12 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
|
| Output Receptacles |
5-15R
5-15/20R |
| Product Features |
Individually Controllable Load Banks
Expandable Runtime |
| Product Highlights |
To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later
120V NEMA 5-20P input, 4 NEMA 5-15R and 4 NEMA 5-15/20R outlets Extended runtime options up to 1600W, 0.9 Power Factor, Interactive LCD interface USB, RS232, EPO and slot for network communication card options 2.2kVA / 2200VA / 1920W line interactive 2U rack/tower UPS, Sine Wave TAA Compliant for GSA Schedule purchases |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110 / 120V
|
| Network Management Cards |
WEBCARDLXE
TLNETCARD |
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.87
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
4.5 min. (1920W)
|
| Communication interface |
USB (HID enabled)
Slot for SNMP / Web interface EPO (emergency power off) DB9 Serial USB and DB9 serial cables included |
| Battery Access |
Front panel battery access door
|
| Typical Battery Runtime |
Expandable Runtime
|
| Expandable Runtime Description |
Extended runtime supported via optional external battery packs; 1600 watts maximum load with external battery packs
|
| Dc Voltage |
48
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
|
| Load Management Receptacles |
Two switched single outlet load banks (1 5-15/20R & 1 5-15R)
|
| High Voltage Transfer to Battery Power |
145
|
| Low Voltage Transfer to Battery Power |
83
|
| Undervoltage Correction |
Voltage boost of 12% applies when input voltage is between 96 and 108
|
| Network UPS Tools (NUT) Compatibility |
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
|
| Application |
Large Network
|
| Switch configuration |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
|
| AC suppression joule rating |
570
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
2.2
|
| Output Capacity (kW) |
1.92
|
| Output Capacity (VA) |
2200
|
| Output Capacity Details |
Output is reduced to 1600 watts maximum when used with external battery packs
|
| Primary UPS Depth (mm) |
490
|
| Primary UPS Height (mm) |
88
|
| Primary UPS Width (mm) |
440
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
|
| Audible Alarms |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| Minimum Required Rack Depth With External Battery Pack |
26
|
| Minimum Required Rack Depth Without External Battery Pack |
24.5
|
| Output Voltage Regulation (Line Mode) |
-14%, +6%
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Voltage reduction of 12% applies when input is between 127 and 145
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90%
|
| Recommended Electrical Service |
20A 120V
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
| Nominal Voltage Details |
120v nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
16
|
| Minimum Required Rack Depth (cm) |
55.88
|
| Minimum Required Rack Depth (inches) |
22
|
| UPS Input Cord Length (m) |
3.1
|
| UPS Power Module Dimensions |
3.46 x 17.32 x 19.29
|
| Power Mode Transfer Time |
5 milliseconds (line to battery mode); 1 millisecond (battery to line mode)
|
| Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
| Optional Accessories |
2 post rackmount (2POSTRMKITWM)
2-4 post front rail rackmount (UPSHDEARKIT) 4 post rackmount short-depth (4POSTRAILKITWM) Tower (2-9USTAND) Wallmount (2POSTRMKITWM) |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-20P
|
| External Battery Pack Compatibility |
BP48V24-2U (limit 1)
BP48V242UTAA (limit 1) BP48V27-2US (multi-pack compatible) BP48V60RT-3U (multi-pack compatible) BP48V60RT3UTAA (multi-pack compatible) |
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks |
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Remote management Hot swappable batteries Auto probe monitoring and reboot (requires WEBCARDLX) Surge/noise protection |