Select your location

Circuit breakers
xPole PFIM Type AC, A, U, R residual current circuit breakers
Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

xPole PFIM Type AC, A, U, R residual current circuit breakers

Eaton offers a complete range of compact residual current devices for fault current/residual current and additional protection in residential and small commercial applications.

xPole PFIM Type AC, A, U, R residual current circuit breakers
Compliant to
IEC/EN 61008
Rated short circuit strength
10 kA
Available types
AC, A, U and R

Core features

  • Compatible with the other devices from the P series, which can be connected by means of a standard busbar
  • Twin-purpose terminal (lift/open-mouthed) at top and bottom
  • Can be positioned on busbar at top or bottom
  • Free terminal space despite installed busbar
  • Z-A universal tripping signal switch (also suitable for PLS and PKN) can be retrofitted
  • Z-HK auxiliary switch can be retrofitted
  • Contact position indicator red - green
  • Time-delayed types suitable for use with standard fluorescent lamps, with or without electronic ballast (30mA-RCD: 30 units per phase conductor, 100mARCD: 90 units per phase conductor)
  • The installation position does not affect the functioning of the device
  • Since tripping does not depend on the mains voltage,
    this RCD is suitable for “fault current/residual current protection” as well as “additional protection” within the meaning of the applicable standards
  • Mains connection at either side
  • The 4-pole device can also be used for 2- or 3-pole connection
The PFIM xPole RCCB is available in following different types:
Magnet motor electricity
Type -A:
Protects against special forms of residual pulsating DC which have not been smoothed.
   
Type -R:
To avoid unwanted tripping due to X-ray devices.




 
134473914
Type -G:
High reliability against unwanted tripping. Compulsory for any circuit where personal injury or damage to property may occur in case of unwanted tripping.

Type -S:
Selective residual current device sensitive to AC, type -S.

Type -S/A:
Additionally protects against special forms of residual pulsating DC which have not been smoothed.

Heathcare - medical
Type -G/A:
Additionally protects against special forms of residual pulsating DC which have not been smoothed. Special types for X-ray application PFIM-...-R.
Type -U:
Suitable for speed-controlled drives with frequency converters in household, trade, and industry. Unwanted tripping is avoided thanks to a tripping characteristic designed particularly for frequency converters.

 

Reliable protection for machines

These products provide an optimal system and additional protection against residual earth leakage currents for a wide range of applications by offering different tripping characteristics to cater for various electrical systems and components that can generate. Available in a comprehensive range of nominal current values and with optional accessories.

Suitable RCD type

The tripping is line voltage-independent. Consequently, the RCD is suitable for “fault current/residual current protection” and “additional protection” within the the meaning of the applicable installation rules.
How to buy from Eaton
Contact us

Phone +40 21 361 0909