Electronic Ballasts including CG-S Monitoring for emergency lighting
Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Electronic Ballasts including CG-S Monitoring for emergency lighting

High-frequency electronic ballasts for 4-pin fluorescent lamps/tubes with 20 addresses for function monitoring (CEWA GUARD Technology) and switching modes (maintained/non-maintained and switched emergency luminaires).

Making them freely programmable in one circuit without additional data line to the luminaires in conjunction with suitable emergency lighting systems (with STAR-Technology).

Electronic Ballasts including CG-S Monitoring for emergency lighting
after lamp exchanging
Automatic re-engagement
Ambient temperature
Enlarged range
STAR-Technology
Reduced installation costs

Features EVG 13.3 V-CG-S, EVG 18V-CG-S, EVG 18C V-CG-S

  • Low operating costs due to decreased standby losses < 0.5 W
  • Without protective conductor connection. For the use in luminaires with insulation class I or II
  • Avoidance of installation failures due to a mains connection being protected against polarity reversal
  • Shortened inspection effort due to the CEWA GUARD and S+-Technology: Automatic function monitoring of up to 20 luminaires per circuit
  • Reduced installation costs due to STAR-Technology: Freely programmable mixed operation of the switching modes per luminaire in one circuit
  • Reduced installation expenditures as no additional data line to the luminaires is needed
  • Enlarged ambient temperature range
eaton-ceag-el-cps-evg-range.png
EVG 13.3 V-CG-S, EVG 18 V-CG-S & EVG 18C V-CG-S

Features N-EVG 36W / 58W V-CG-S

  • Reduced battery capacity / -costs by adjustable luminous flux of 30 – 100% in DC-operation
  • Avoidance of installation failures due to a mains connection being protected against polarity reversal
  • Shortened inspection effort due to CEWA GUARD and S+-Technology: Automatic function monitoring of up to 20 luminaires per circuit
  • Reduced installation costs due to STAR-Technology: Freely programmable mixed operation of switching modes per luminaire in one circuit
  • Reduced installation expenditures as no additional data line to the luminaire are needed
  • With automatic lamp wattage detection and optimal operation of the lamp acc. to IEC-standard
  • Safety by automatic switch off at lamp failures or at end of lamp life
  • Automatic re-engagement after lamp exchanging
eaton-ceag-el-cps-n-evg-group.png
N-EVG 36W & N-EVG 58W

Reduced battery capacity costs with a settable luminous flux ratio

Eaton offers a wide range of special ballasts for emergency lighting for installation into existing light fittings. The ballasts include a monitoring module which signals the luminaire’s current status to the central emergency lighting system. This means that only one ballast must be installed into the luminaire, safe operation in the DC voltage range of 186 - 275 V is ensured, and the danger of specifying the wrong ballast is minimised.

By the use of efficient electronic ballasts with automatically reduced luminous flux in battery operation, a considerable reduction of energy is achieved. This saves costs and adds to environmental protection since it provides equal safety with smaller batteries.

eaton-ceag-el-cps-standard-evg-graphic.jpg
Standard EVG 58W/100% luminous flux
eaton-ceag-el-cps-n-evg-example.jpg
N-EVG 58 W/30% luminous flux
eaton-ceag-el-cps-battery-capacity-evg-graphic.jpg
Luminous flux (left axis) by battery capacity (right axis)

Intelligent modules ensure greater safety

With Eaton monitoring modules, electronic ballasts or LED supply modules, luminaires for general lighting systems from any manufacturer can be connected to central battery systems and thus integrated into the building emergency lighting concept.

The modules matched to the requirements of central battery systems installations make it possible to monitor and control up to 20 luminaires in only one circuit. Using the ballasts, luminaires on one circuit can be operated in different switching modes such as maintained light, non-maintained light or switched maintained light.

Here in the case of the N-EVGs (electronic ballasts), the emergency lighting level of each lamp can be individually set for battery operation from 30 to 100 % of the nominal luminous flux. Addressing and adjustment of the luminous flux are performed, as usual, via easy to access coding switches. Please observe our electronic control gear requirements for monitoring third-party luminaires.

Over 50 years of safe evacuation expertise

Eaton offers a wide range of emergency exit and safety luminaires. Featuring CEWA GUARD & STAR technology available as standard, they offer the basis for minimized inspection and maintenance costs. Innovative lighting technology combined with highly efficient LEDs ensure up to 70% less power consumption and significantly lower maintenance costs with a service life up to 50,000 hours.