Eaton XN Analog input card XI/ON, 24 V DC, 1AI (0/4 to 20mA)
Product Name |
Eaton XN Accessory Input card
|
Catalog Number |
140063
|
EAN |
7640130120037
|
Product Length/Depth |
55.4 mm
|
Product Height |
74.1 mm
|
Product Width |
12.6 mm
|
Product Weight |
0.035 kg
|
Certifications |
UL 508
IEC/EN 61131-2 CSA Class No.: 2252-01, 2252-81 UL report applies to both US and Canada cULus UL Category Control No.: NRAQ, NRAQ7 IEC/EN 6113-2 UL File No.: E205091 CE Certified by UL for use in Canada IEC/EN 61000-6-4 UL Recognized IEC/EN 61000-6-2 CSA-C22.2 No. 142 |
Model Code |
XN-1AI-I(0/4...20MA)
|
Used with |
XN-S4T-SBBS
XN-S3T-SBB XN-S4S-SBBS XN-S3S-SBB |
Type |
XI/ON I/O module
|
Features |
Measuring principle: Successive approximation
Analog outputs configurable Fieldbus connection over separate bus coupler possible Input, current Analog inputs configurable Input signal, configurable |
Air discharge |
According to EN 61100-4-2
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Screw-/spring clamp connection
|
Burst impulse |
According to IEC/EN 61000-4-4
|
Number of channels |
1
|
Resolution |
14-bit (signed integer, Resolution of the A/D converter)
|
Explosion safety category for dust |
None
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Resolution of the analog inputs |
16 Bit
|
Resolution of the analog outputs |
0 Bit
|
Static heat dissipation, non-current-dependent Pvs |
1 W
|
Supply voltage at AC, 50 Hz - max |
0 VAC
|
Supply voltage at AC, 50 Hz - min |
0 VAC
|
Supply voltage at AC, 60 Hz - max |
0 VAC
|
Supply voltage at AC, 60 Hz - min |
0 VAC
|
Supply voltage at DC - max |
28.8 VDC
|
Supply voltage at DC - min |
20.4 VDC
|
Product category |
XN Slice module
|
Environmental conditions |
Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)
Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation) |
Input |
Linked to L+ and L- of the supply, not short-circuit protected (Encoder Supply, Analog inputs)
|
Explosion safety category for gas |
None
|
Mounting method |
Rail mounting possible
|
Current consumption |
50 mA, from supply terminal
41 mA, from module bus, Analog input modules |
Voltage type |
DC
|
Contact discharge |
According to EN 61100-4-2
|
Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
Emitted interference |
30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)
230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3) |
Potential isolation |
Through optocoupler: yes
|
Electromagnetic fields |
According to IEC EN 61100-4-2
|
Number of inputs (analog) |
1
|
Radiated RFI |
IEC/EN 61100-4-6
|
Drop and topple |
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
|
Protocol |
Other bus systems
|
Relative humidity |
5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
|
Timing cycle |
0.1 % Offset error
|
Repetition accuracy |
0.09 % (deviation)
|
Rated operational voltage |
24 V DC (supply terminal)
|
Degree of protection |
IP20
NEMA 1 |
Vibration resistance |
According to IEC/EN 60068-2-6
|
Input impedance |
< 125 Ω
|
Shock resistance |
Continuous according to IEC/EN 60068-2-29
Mechanical, According to IEC/EN 60068-2-27 |
Functions |
Diagnosis function
|
Suitable for |
Base modules without C-Connection: 2-/3-wire
Base modules without C-Connection, for sensor feeding: 4-wire |
Number of bytes |
3 parameter bits
|
System accessory |
Yes
|
Input current |
0/4 - 20 mA (Analog input)
50 mA (Analog input) |
Voltage dips |
According to EN 61131-2 (Voltage fluctuations/voltage dips)
|
Safety performance level (EN ISO 13849-1) |
None
|
SIL (IEC 61508) |
None
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
0 °C
|
Ambient storage temperature - max |
85 °C
|
Ambient storage temperature - min |
-25 °C
|
Equipment heat dissipation, current-dependent Pvid |
1 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Linearity |
0.03 %
|
Number of HW-interfaces (industrial ethernet) |
0
|
Number of HW-interfaces (other) |
1
|
Number of HW-interfaces (parallel) |
0
|
Number of HW-interfaces (RS-232) |
0
|
Number of HW-interfaces (RS-422) |
0
|
Number of HW-interfaces (RS-485) |
0
|
Number of HW-interfaces (serial TTY) |
0
|
Number of HW-interfaces (USB) |
0
|
Number of HW-interfaces (wireless) |
0
|
Number of interfaces (PROFINET) |
0
|
Number of outputs (analog) |
0
|
Limit frequency |
200 Hz (- 3 db)
|
Measured value representation |
16-bit signed integer
12-bit full range left-justified |
Measured variables |
Current
|