Select your location

Serial Number Verified :
Authenticated:
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

XD Deflection Couplings

XD deflection couplings from Eaton's Crouse-Hinds Division can be installed indoors, outdoors, buried underground or embedded in concrete in non-hazardous areas.  XDs provide a flexible and watertight connection for protection of conduit wiring systems from damage due to movement.  They are used with standard rigid conduit or PVC rigid conduit (PVC requires rigid metal conduit nipples and rigid metal-to-PVC conduit adapters).  XDs are also available with a hot dip galvanized finish for added corrosion protection against harsh environmental factors.

Typical applications for XD deflection couplings include underground conduit feeder runs, runs between sections of concrete subject to relative movement, runs between fixed structures, conduit entrances in high rise buildings, bridges, marinas, docks and piers.

XD Deflection Couplings

Certifications and compliances

  • UL standard: 514B
  • CSA 22.2 No. 18 3-12
  • Wet locations

Design features

  • XD couplings accommodate the following movements without collapsing or fracturing the conduit, and damaging the wires it contains:
    1. Axial expansion or contraction up to 3/4”
    2. Angular misalignment of the axes of the coupled conduit runs in any direction to 30°
    3. Parallel misalignment of the axes of coupled conduit runs in any direction to 3/4”
  • Inner sleeve maintains constant I.D. in any position and provides a smooth insulated wireway for protection of wire insulation
  • Watertight flexible neoprene outer jacket is corrosion-resistant and protects the grounding strap and the attachment points of the hubs
  • Tinned copper flexible braid grounding straps assure grounding continuity
  • Stainless steel jacket clamps for strength and corrosion resistance
  • Standard tapered electrical threads fit standard rigid conduit
  • Integral hub bushing protects insulation of conductors

Standard materials

  • Hubs – Feraloy iron alloy, electrogalvanized
  • Outer jacket – molded neoprene, natural (black)
  • Jacket clamps – stainless steel, natural
  • Inner sleeve – molded plastic, natural (brown)
  • Bonding strap – braided tinned copper

Drawings and design support

How to buy from Eaton
Locate a channel partner

Find an authorized distributor or sales rep near you

Questions before you buy

Email us using the link above, or call our Customer Support team at 1-866-764-5454