1050VA 540W 120V Line-Interactive UPS - 12 NEMA 5-15R Outlets, Double-Boost AVR, USB, Desktop/Wall-Mount
| Product Name |
Eaton Tripp Lite series UPS
|
| Catalog Number |
OMNISMART1050MX
|
| UPC |
037332258182
|
| Product Length/Depth |
15 in
|
| Product Height |
10.71 in
|
| Product Width |
6.3 in
|
| Product Weight |
14.55 lb
|
| Compliances |
ENERGY STAR certified
RoHS EAC FCC Class A FCC Class B |
| Certifications |
RETIE
UL 1778 CSA certified NOM |
| Global Catalog |
OMNISMART1050MX
|
| Product Type |
UPS
|
| Topology |
Line-interactive
|
| Rack size |
0U
|
| Package contents |
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz (±3%)
|
| Receptacle |
5-15R
|
| Electric current - max |
12A
|
| Relative humidity |
0-90% non-condensing
|
| Output Receptacles |
5-15R
|
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Output power factor |
0.6
|
| Communication interface |
USB (HID enabled)
USB interface cable included |
| Battery Access |
Battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB interface cable included
|
| Grounding Details |
Includes side-panel grounding lug
|
| Input Circuit Breakers |
15A @ 120V
|
| Undervoltage Correction |
Input voltages between 93 and 108 are boosted by 13%
|
| Application |
Home/Office Desktop
|
| Switch configuration |
Switch supports On/Off power control (release after 3 seconds), UPS battery-test (line mode only, release after 5 seconds), Alarm-mute (battery mode only, release after 0.5 seconds)
|
| AC suppression joule rating |
600
|
| Output current |
8.8A @ 120V~
|
| Output Capacity Details |
Supports 125% load for 10 minutes, 20 seconds (load PF=1.0); Supports 110% for up to 27 seconds
|
| Operating Elevation |
Up to 3000m
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Manual alarm-cancel supported
|
| Audible Alarms |
Alarm sounds to report Battery-mode operation, Low-battery status, Overload status and UPS Battery test modelow-battery, fault, overload and replace-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Replaceable internal batteries (see manual)
|
| LED Indicators |
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions (see manual)
|
| Frequency Rating Details |
60 Hz (±3%) tolerance
|
| Overvoltage Correction |
Input voltages between 128 and 152 are cut by 16%
|
| Rechargeable Battery |
5 hours to 90%
|
| Storage Temperature |
5° to 113°F (-15° to 45°C )
|
| Input Nominal Voltage Description |
Supports input voltages from 78 to 152V
|
| Nominal Voltage Details |
120v nominal output in AC and battery modes
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 78 to 152
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Input Nominal Voltage |
120 VAC
|
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Surge/noise protection |
Support from Eaton