750VA 460W 120V Line-Interactive UPS - 12 NEMA 5-15R Outlets, Double-Boost AVR, USB, Desktop/Wall-Mount
| Product Name |
Eaton Tripp Lite series UPS
|
| Catalog Number |
OMNISMART750MX
|
| UPC |
037332258175
|
| Product Length/Depth |
15 in
|
| Product Height |
10.71 in
|
| Product Width |
6.3 in
|
| Product Weight |
13.45 lb
|
| Compliances |
RoHS
FCC Class A ENERGY STAR certified EAC SASO CE Marked |
| Certifications |
UL 1778
NOM RETIE CSA certified GoST-R IEC/EN 62040-1 IRAM |
| Global Catalog |
OMNISMART750MX
|
| Product Type |
UPS
|
| Topology |
Line-interactive
|
| Rack size |
0U
|
| VA rating |
750 VA
|
| Package contents |
|
| Input nominal voltage |
120V AC
|
| Nominal frequency |
60 Hz
|
| Input frequency range |
60 Hz
|
| Receptacle |
5-15R
|
| Output nominal voltage |
120V
|
| Electric current - max |
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
11 min
|
| Relative humidity |
0-90% non-condensing
|
| Input Plug Type |
NEMA 5-15P
|
| Output Receptacles |
5-15R
|
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
120V
|
| Network Management Cards Details |
Network management not supported
|
| Output power factor |
0.6
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
3.6 min. (460W)
|
| Communication interface |
USB (HID enabled)
USB interface cable included |
| Battery Access |
Battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB interface cable included
|
| Grounding Details |
Includes side-panel grounding lug
|
| Input Circuit Breakers |
10A @ 120V
|
| High Voltage Transfer to Battery Power |
152
|
| Low Voltage Transfer to Battery Power |
78
|
| Undervoltage Correction |
Input voltages between 93 and 108 are boosted by 13%
|
| Application |
Home/Office Desktop
|
| Switch configuration |
Switch supports On/Off power control (release after 3 seconds), UPS battery-test (line mode only, release after 5 seconds), Alarm-mute (battery mode only, release after 0.5 seconds)
|
| AC suppression joule rating |
600
|
| Output AC waveform (AC mode) |
Pure sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
0.75
|
| Output Capacity (Watts) |
460
|
| Output Capacity Details |
Supports 125% load for 10 minutes, 20 seconds (load PF=1.0); Supports 110% for up to 27 seconds
|
| Operating Elevation |
Up to 3000m
|
| Primary UPS Depth (mm) |
305
|
| Primary UPS Height (mm) |
105
|
| Primary UPS Width (mm) |
190
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Manual alarm-cancel supported
|
| Audible Alarms |
Alarm sounds to report Battery-mode operation, Low-battery status, Overload status and UPS Battery test modelow-battery, fault, overload and replace-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Replaceable internal batteries (see manual)
|
| LED Indicators |
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions (see manual)
|
| Frequency Rating Details |
60 Hz (±3%) tolerance
|
| Output Voltage Regulation (Line Mode) |
120V~ (+8% / -15%)
|
| Output Voltage Regulation(Battery Mode) |
120V (±5%)
|
| Overvoltage Correction |
Input voltages between 128 and 152 are cut by 16%
|
| Rechargeable Battery |
5 hours to 90%
|
| Storage Temperature |
5° to 113°F (-15° to 45°C )
|
| Input Nominal Voltage Description |
Supports input voltages from 78 to 152V
|
| Nominal Voltage Details |
120v nominal output in AC and battery modes
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 78 to 152
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
10
|
| UPS Input Cord Length (m) |
2.1
|
| UPS Power Module Dimensions |
4.14 x 7.48 x 12
|
| Power Mode Transfer Time |
2-6 milliseconds (typical), 10 milliseconds (max)
|
| Total Outlets |
12
|
| Output Capacity (VA) |
750
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
Right-Angled |
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
| UPS Dataline Suppression |
1 line TEL/DSL or Ethernet
|
| UPS Output Receptacles |
6 UPS outlets, 6 surge-only outlets
|
| High Availability UPS Features |
Surge/noise protection
Automatic voltage regulation (AVR) |
| Nominal Input Voltage Supported |
120V AC
|
Support from Eaton