Download document () of 20
We make what matters work*

OMNISMART750MX

750VA 460W 120V Line-Interactive UPS - 12 NEMA 5-15R Outlets, Double-Boost AVR, USB, Desktop/Wall-Mount

  • Protects equipment against blackouts, brownouts, transient surges and line noise
  • Keeps AC power running during blackouts to allow time for file saves and safe shutdown
  • High >98.3% efficiency and low BTU ratings save electricity and lower your energy costs
  • 12 NEMA 5-15R outlets power and protect PC, home theater or digital signage equipment
  • Double-boost AVR maintains 120V nominal output during brownouts and overvoltages

General specifications

Product Name
Eaton Tripp Lite series UPS
Catalog Number
OMNISMART750MX
UPC
037332258175
Product Length/Depth
15 in
Product Height
10.71 in
Product Width
6.3 in
Product Weight
13.45 lb
Compliances
RoHS
FCC Class A
ENERGY STAR certified
EAC
SASO
CE Marked
Certifications
UL 1778
NOM
RETIE
CSA certified
GoST-R
IEC/EN 62040-1
IRAM
Global Catalog
OMNISMART750MX
Product Type
UPS

Product specifications

Topology
Line-interactive
Rack size
0U
VA rating
750 VA
Package contents
  • OMNISMART750MX 750VA 460W 120V Line-Interactive UPS with 12 Outlets
  • USB cable
  • Owner’s manual
Input nominal voltage
120V AC
Nominal frequency
60 Hz
Input frequency range
60 Hz
Receptacle
5-15R
Output nominal voltage
120V
Electric current - max
  • 10A
  • 10
Battery type
Valve Regulated Lead Acid (VRLA)
Runtime at half load
11 min
Relative humidity
0-90% non-condensing
Input Plug Type
NEMA 5-15P
Output Receptacles
5-15R
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Nominal Output Voltage
120V
Network Management Cards Details
Network management not supported
Output power factor
0.6
Phase (input)
Single-phase
Runtime at full load
3.6 min. (460W)
Communication interface
USB (HID enabled)
USB interface cable included
Battery Access
Battery access door
Dc Voltage
12
Operating Temperature Range
32° to 104°F (0° to 40°C)
Communications Cable
USB interface cable included
Grounding Details
Includes side-panel grounding lug
Input Circuit Breakers
10A @ 120V
High Voltage Transfer to Battery Power
152
Low Voltage Transfer to Battery Power
78
Undervoltage Correction
Input voltages between 93 and 108 are boosted by 13%
Application
Home/Office Desktop
Switch configuration
Switch supports On/Off power control (release after 3 seconds), UPS battery-test (line mode only, release after 5 seconds), Alarm-mute (battery mode only, release after 0.5 seconds)
AC suppression joule rating
600
Output AC waveform (AC mode)
Pure sine wave
Output AC waveform (battery mode)
PWM sine wave
Output Capacity (kVA)
0.75
Output Capacity (Watts)
460
Output Capacity Details
Supports 125% load for 10 minutes, 20 seconds (load PF=1.0); Supports 110% for up to 27 seconds
Operating Elevation
Up to 3000m
Primary UPS Depth (mm)
305
Primary UPS Height (mm)
105
Primary UPS Width (mm)
190
AC Suppression Response Time
Instantaneous
Alarm Interface
Manual alarm-cancel supported
Audible Alarms
Alarm sounds to report Battery-mode operation, Low-battery status, Overload status and UPS Battery test modelow-battery, fault, overload and replace-battery conditions
Battery Start Capability
Cold-start operation supported
Battery Replacement Description
Replaceable internal batteries (see manual)
LED Indicators
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions (see manual)
Frequency Rating Details
60 Hz (±3%) tolerance
Output Voltage Regulation (Line Mode)
120V~ (+8% / -15%)
Output Voltage Regulation(Battery Mode)
120V (±5%)
Overvoltage Correction
Input voltages between 128 and 152 are cut by 16%
Rechargeable Battery
5 hours to 90%
Storage Temperature
5° to 113°F (-15° to 45°C )
Input Nominal Voltage Description
Supports input voltages from 78 to 152V
Nominal Voltage Details
120v nominal output in AC and battery modes
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 78 to 152
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Maximum Input Amps
10
UPS Input Cord Length (m)
2.1
UPS Power Module Dimensions
4.14 x 7.48 x 12
Power Mode Transfer Time
2-6 milliseconds (typical), 10 milliseconds (max)
Total Outlets
12
Output Capacity (VA)
750
EMI AC Noise Suppression
EMI / RFI AC Noise Suppression
UPS Input Connection Type
5-15P
Right-Angled
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS
UPS Dataline Suppression
1 line TEL/DSL or Ethernet
UPS Output Receptacles
6 UPS outlets, 6 surge-only outlets
High Availability UPS Features
Surge/noise protection
Automatic voltage regulation (AVR)
Nominal Input Voltage Supported
120V AC