1500VA 900W 230V OmniVS Line-Interactive UPS - 8 C13 Outlets, 2 Australian Outlet Adapters, LCD, USB, Tower
| Product Name |
Eaton Tripp Lite series UPS
|
| Catalog Number |
OMNIVSX1500A
|
| UPC |
037332255242
|
| Product Length/Depth |
15.4 in
|
| Product Height |
11.3 in
|
| Product Width |
7.5 in
|
| Product Weight |
22 lb
|
| Compliances |
CE Marked
RoHS |
| Certifications |
AS/NZS 4417
|
| Global Catalog |
OMNIVSX1500A
|
| Product Type |
UPS
|
| Topology |
Line-interactive
|
| Rack size |
0U
|
| Package contents |
|
| Nominal frequency |
50/60 Hz
|
| Receptacle |
C13
|
| Electric current - max |
6.5
|
| Battery replacement |
RBC51 (qty 2)
|
| Noise level |
Less than 40dB front side 1m
|
| Relative humidity |
Up to 90% non-condensing
|
| Front Panel LCD Display |
Touchscreen LCD indicates input voltage, output voltage, output load percentage and battery charge percentage; Supports additional fault reporting (see manual); Touchscreen LCD remains lighted for 20 seconds in line power mode after any user interaction and remains lighted full time in battery mode
|
| Output Receptacles |
C13
|
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Communication interface |
USB (HID enabled)
USB cabling included |
| Dc Voltage |
24
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB cabling included
|
| Input Circuit Breakers |
10A fuse
|
| Undervoltage Correction |
Input voltages between 170 and 207 are boosted by 18%
|
| Application |
|
| Switch configuration |
Power switch offers whole UPS off/on power control
|
| Hot Swap PDU Options |
PDUBHV10 (2U / 8 C13 outlets)
|
| AC suppression joule rating |
312
|
| Housing material |
ABS
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Alarm remains silent in battery power mode until low-battery condition occurs
|
| Audible Alarms |
Audible alarm indicates low-battery condition during battery mode operation
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
See manual for battery replacement information
|
| Frequency Rating Details |
Automatic frequency selection
|
| Overvoltage Correction |
Input voltages between 247 and 280 are reduced by 15%
|
| Rechargeable Battery |
Less than 8 hours from 10% to 90%
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
| Nominal Voltage Details |
230V nominal output in battery mode
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Input Nominal Voltage |
230 VAC
|
| High Availability UPS Features |
Automatic voltage regulation (AVR)
Surge/noise protection |
Support from Eaton