Download document () of 20
We make what matters work*
To be discontinued

OMNIVSX650A

650VA 360W 230V Line-Interactive UPS - 4 C13 Outlets, 2 Australian Outlet Adapters, Tower

  • 4 C13 outlets with 2 AUS/NZ adapters power and protect PCs and other equipment
  • Protects equipment against blackouts, brownouts, transient surges and line noise
  • Keeps AC power running during outages to allow time for file saves and safe shutdown
  • Easy-to-see LEDs indicate line, battery, overload and fault conditions at a glance
  • Maintains line power operation with input voltage as low as 170V and as high as 280V

General specifications

Product Name
Eaton Tripp Lite series UPS
Catalog Number
OMNIVSX650A
UPC
037332255211
Product Length/Depth
13.5 in
Product Height
5.7 in
Product Width
9.1 in
Product Weight
10.6 lb
Compliances
RoHS
CE Marked
Certifications
AS/NZS 4417
Global Catalog
OMNIVSX650A
Product Type
UPS

Product specifications

Topology
Line-interactive
Rack size
0U
Package contents
  • OMNIVSX650A 650VA 360W 230V Line-Interactive UPS with 4 Outlets
  • (2) C13 to AUS/NZ outlet adapters, 30 cm
  • Power cord with 10A AUS/NZ plug, 1.5 m
  • Owner's manual
Nominal frequency
50/60 Hz
Receptacle
C13
Electric current - max
2.8A
Relative humidity
Up to 90% non-condensing
Output Receptacles
C13
Communication interface
None
Dc Voltage
12
Operating Temperature Range
32° to 104°F (0° to 40°C)
Input Circuit Breakers
5A fuse
Undervoltage Correction
Input voltages between 170 and 207 are boosted by 18%
Application
Home/Office Desktop
Switch configuration
1 Switch controls off/on power status
AC suppression joule rating
312
Housing material
PVC
Operating Elevation
0-2000m
AC Suppression Response Time
Instantaneous
Audible Alarms
Audible alarm with distinct tone patterns indicates low-battery, overload, replace-battery and fault-mode
Battery Start Capability
Yes
Battery Replacement Description
See manual for battery replacement information
LED Indicators
3 front panel LEDs indicate off/on power status, line power availability, battery mode operation, overload, replace-battery and fault-mode
Frequency Rating Details
Automatic frequency selection
Overvoltage Correction
Input voltages between 253 and 280 are reduced by 15%
Rechargeable Battery
8 hours from 10% to 90%
Storage Temperature
5° to 122°F (-15° to 45°C)
Nominal Voltage Details
230V nominal output in battery mode
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 170 and as high as 280
Input Nominal Voltage
230 VAC
High Availability UPS Features
Surge/noise protection
Automatic voltage regulation (AVR)