12.6kW 3-Phase Local Metered PDU, 208V Outlets (36 C13 & 9 C19) Hubbell 50A CS8365C, 6 ft. (1.83 m) Cord, 0U Vertical, TAA
| Product Name |
Eaton Tripp Lite series local metered PDU
|
| Catalog Number |
PDU3MV6H50
|
| UPC |
037332163868
|
| Product Length/Depth |
2.65 in
|
| Product Height |
70 in
|
| Product Width |
2.2 in
|
| Product Weight |
14.49 lb
|
| Warranty |
2 year limited
|
| Compliances |
RoHS
FCC Class A TAA Compliant |
| Certifications |
NOM
UL 62368-1 RETIE |
| Global Catalog |
PDU3MV6H50
|
| Product Type |
Local metered PDU
|
| Form factor |
0U (Vertical)
|
| Package contents |
|
| Operating Temperature |
32° to 104°F (0° to 40°C)
|
| Mounting direction |
Vertical
|
| Material |
Metal
|
| Input connection |
HUBBELL CS8365C 50A
|
| Cord length |
6 ft
|
| Amperage Rating |
35A
|
| Electric current - max |
35
|
| Phase |
Three-phase
|
| Frequency rating |
50/60 Hz
|
| Number of Outputs C13 |
36
|
| Number of Outputs C19 |
9
|
| Features |
Flex Center
|
| Front Panel LCD Display |
Set of 3 digital current meters report current in amps for each output phase
|
| Output Receptacles |
C13
C19 |
| Overload protection |
Three 20A circuit breakers, 1 per outlet bank
|
| Recommended electrical service |
Three-phase 50A 208V service
|
| Reported load Segments |
Supports local monitoring of current for each output phase (20A balanced max per L1-L2, L2-L3 and L3-L1); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 feeds black outlets; L2-L3 feeds dark-gray outlets; L3-L1 feeds light-gray outlets
|
| Output Receptacles Details |
Compatible with Eaton Tripp Lite Power Cords
|
| Receptacles |
|
| Input Cord Length |
6 ft
|
| TAA Compliance |
Yes
|
| Product Features |
TAA Compliant
|
| Amperage Rating Details |
Agency de-rated to 35A continuous
|
| Operating elevation |
0-10000 ft. (0-3000 m)
|
| Operating temperature range |
32° to 104°F (0° to 40°C)
|
| Output nominal voltage |
208V
|
| Relative humidity |
5% to 95% non-condensing
|
| Form Factors Supported |
Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
|
| Output Capacity Details |
12.6kVA (208V) total capacity; 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
|
| Output Capacity (kW) |
12.6
|
| Storage temperature |
-22° to 140°F (-30° to 60°C)
|
| PDU Plug Type |
CS8365
|
| PDU Type |
Local metered
|
| PDU Input Voltage |
208
|
| PDU Form Factor |
Vertical (0U)
|
| Total Outlets |
45
|
Support from Eaton