Eaton Moeller® series RS Safety switch, RS, 1 N/O, 1 NC, Reed contacts, Ue 24 V DC, -10 - +55 °C, Plastic, Connecting cable 150 mm with plug connection M12 x 1, Sn 8 - 19 mm, R
| Product Name | 
                                                Eaton Moeller® series RS Safety switch
                                             | 
| Catalog Number | 
                                                177296
                                             | 
| EAN | 
                                                4015081717491
                                             | 
| Product Length/Depth | 
                                                52 mm
                                             | 
| Product Height | 
                                                13 mm
                                             | 
| Product Width | 
                                                26 mm
                                             | 
| Product Weight | 
                                                0.057 kg
                                             | 
| Certifications | 
                                                Certified by UL for use in Canada  UL File No.: E166051 UL CE CSA File No.: UL report applies to both US and Canada EN ISO 13849 UL Category Control No.: NRKH, NRKH7 ISO 14119 IEC 62061 | 
| Catalog Notes | 
                                                Reed contacts
                                             | 
| Type | 
                                                Safety position switch
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Electric connection type | 
                                                Connector M12
                                             | 
| Enclosure material finishing | 
                                                Plastic-coated
                                             | 
| Enclosure material | 
                                                Plastic
                                             | 
| Enclosure type | 
                                                Cuboid
                                             | 
| Rated operational current (Ie) at DC-13, 125 V | 
                                                0 A
                                             | 
| Rated operational current (Ie) at DC-13, 220 V, 230 V | 
                                                0 A
                                             | 
| Rated operational current (Ie) at DC-13, 24 V | 
                                                0.3 A
                                             | 
| Rated switching distance (Sn) - max | 
                                                19 mm
                                             | 
| Rated switching distance (Sn) - min | 
                                                8 mm
                                             | 
| Sensor height | 
                                                13 mm
                                             | 
| Sensor length | 
                                                52 mm
                                             | 
| Width sensor | 
                                                26 mm
                                             | 
| Product category | 
                                                Non-contacting safety switch
                                             | 
| Action | 
                                                2020122120328-Mechanical Limit Switches.xlsm-Data
                                             | 
| Explosion safety category for dust | 
                                                None
                                             | 
| Explosion safety category for gas | 
                                                None
                                             | 
| Ambient operating temperature - max | 
                                                55 °C
                                             | 
| Ambient operating temperature - min | 
                                                -10 °C
                                             | 
| Equipment heat dissipation, current-dependent Pvid | 
                                                0 W
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Number of contacts (change-over contacts) | 
                                                0
                                             | 
| Number of contacts (normally closed contacts) | 
                                                1
                                             | 
| Number of contacts (normally open contacts) | 
                                                1
                                             | 
| Number of safety auxiliary contacts | 
                                                1
                                             | 
| Rated operational current (Ie) at AC-15, 125 V | 
                                                0 A
                                             | 
| Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V | 
                                                0 A
                                             | 
| Rated operational current (Ie) at AC-15, 24 V | 
                                                0 A
                                             | 
| Mounting position | 
                                                As required
                                             | 
| Material | 
                                                Plastic
                                             | 
| Connection type | 
                                                Plug-in connection M12 x 1
                                             | 
| Degree of protection | 
                                                IP67  NEMA Other | 
| Interface type | 
                                                None
                                             | 
| Terminal capacity (AWG) | 
                                                22
                                             | 
| Relative humidity | 
                                                90 % (at 55 °C)
                                             | 
| Rated operational voltage | 
                                                24 V DC
                                             | 
| Repetition accuracy | 
                                                ≤ 10 % (deviation)
                                             | 
| Shock resistance | 
                                                30 g, Shock duration 11 ms, Half-Sinusoidal
                                             | 
| Suitable for | 
                                                Safety functions
                                             | 
| Vibration resistance | 
                                                0 - 2000 Hz, 1 mm
                                             | 
| Safety parameter (EN ISO 13849-1) | 
                                                20,000,000 switching cycles, B10d  PL e, Performance level | 
| Safety parameter (IEC 62061) | 
                                                SIL: 3
                                             | 
| Switching contact type | 
                                                Other
                                             |