Eaton Moeller® series EMR6 Phase imbalance monitoring relays, 300 - 500 V AC, 50/60 Hz
| Product Name | 
                                                Eaton Moeller® series EMR6 Asymmetry monitoring relay
                                             | 
| Catalog Number | 
                                                184762
                                             | 
| EAN | 
                                                4015081787982
                                             | 
| Product Length/Depth | 
                                                103.7 mm
                                             | 
| Product Height | 
                                                85.6 mm
                                             | 
| Product Width | 
                                                22.5 mm
                                             | 
| Product Weight | 
                                                0.16 kg
                                             | 
| Certifications | 
                                                IEC/EN 60255-6  UL IEC255-6 CE | 
| Type | 
                                                Phase imbalance monitoring relay
                                             | 
| Features | 
                                                Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages
                                             | 
| Air discharge | 
                                                Air/contact discharge, according to IEC/EN 61000-4-2, level 3
                                             | 
| Electric connection type | 
                                                Screw connection
                                             | 
| Pollution degree | 
                                                3
                                             | 
| Power consumption | 
                                                15 VA
                                             | 
| Burst impulse | 
                                                According to IEC/EN 61000-4-4, level 3
                                             | 
| Climatic proofing | 
                                                Damp heat, cyclic, to IEC 60068-2-30
                                             | 
| Rated impulse withstand voltage (Uimp) | 
                                                4000 V AC
                                             | 
| Adjustable delay-on energization time - min | 
                                                0.1 s
                                             | 
| Adjustable off-delay time - min | 
                                                0 s
                                             | 
| Ambient operating temperature - max | 
                                                60 °C
                                             | 
| Ambient operating temperature - min | 
                                                -25 °C
                                             | 
| Ambient storage temperature - max | 
                                                85 °C
                                             | 
| Ambient storage temperature - min | 
                                                -40 °C
                                             | 
| Number of contacts (change-over contacts) | 
                                                2
                                             | 
| Number of contacts (normally closed contacts) | 
                                                0
                                             | 
| Number of contacts (normally open contacts) | 
                                                0
                                             | 
| Permitted delay-on energization time - max | 
                                                30 s
                                             | 
| Permitted off-delay time - max | 
                                                0 s
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                                500 V
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                                300 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                                500 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                                300 V
                                             | 
| Rated operational current (Ie) | 
                                                3 A at AC-15, 230 V  2 A at DC-13, 24 V 4 A at AC-12, 230 V 4 A at DC-12, 24 V | 
| Lifespan, electrical | 
                                                300,000 Operation (at 230 V, AC-12, 4 A)
                                             | 
| Screwdriver size | 
                                                5.5 x 0.8 mm, Terminal screw
                                             | 
| Voltage type | 
                                                AC
                                             | 
| Connection type | 
                                                Snap fixing, top-hat rail IEC/EN 60715
                                             | 
| Mounting position | 
                                                As required
                                             | 
| Shock resistance | 
                                                Class 2
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Short-circuit protection rating | 
                                                Max. 10 A Fast/gL, Fuse, Relay output contacts
                                             | 
| Duty factor | 
                                                100 %, Power supply
                                             | 
| Degree of protection | 
                                                Terminals: IP20  Enclosure: IP50 | 
| Supply voltage | 
                                                300 - 500 V AC, 50/60 Hz
                                             | 
| Delay time | 
                                                0.2 s, Response delay time  On delay: None = 0 or adjustable from 0.1 to 30 s | 
| Surge rating | 
                                                According to IEC/EN 61000-4-5 Level 4
                                             | 
| Electromagnetic compatibility | 
                                                According to IEC/EN 60947-6-2
                                             | 
| Temperature error | 
                                                0.06 %/°C, Measuring circuits
                                             | 
| Monitoring voltage | 
                                                300 - 500 V AC, 50/60 Hz (per phase)
                                             | 
| Functions | 
                                                Phase failure detection
                                             | 
| Hysteresis | 
                                                20 %
                                             | 
| Immunity to line-conducted interference | 
                                                Level 3 (according to IEC/EN 61000-4-6)
                                             | 
| Tightening torque | 
                                                Min. 0.5 Nm, Screw terminals  0.8 Nm, Screw terminals | 
| Immunity to radiation | 
                                                Level 3 (according to IEC/EN 61000-4-3)
                                             | 
| Voltage tolerance | 
                                                0.85 x Uc  1.1 x Uc | 
| Timing cycle | 
                                                0.06 %/°C, Time error within temperature range  Adjustable from 0.1 – 30 s, Reset delay/Off-delay time 0.5 % Error within supply voltage (Measuring circuits) 0.5 %, Time error within supply voltage | 
| LED indicator | 
                                                Status indication of energized output relay: Yellow LED  Status indication of Supply voltage: Green, solid light Status indication of Imbalance: Red, solid light (F1 and F2) Status indication of errors: Red LED Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating) Status indication of Relay energized: Yellow, solid light Status indication of Phase failure: F1 red, solid light and F2 red, flashing light Status indication of Delay time running: Yellow, flashing light | 
| Lifespan, mechanical | 
                                                30,000,000 Operations
                                             | 
| Monitoring function | 
                                                Phase sequence  Phase failure Phase imbalance monitoring Imbalance Phase sequence monitoring | 
| Rated control supply voltage (Us) at DC - max | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at DC - min | 
                                                0 V
                                             | 
| Rated frequency - max | 
                                                60 Hz
                                             | 
| Rated frequency - min | 
                                                50 Hz
                                             | 
| Rated operational voltage (Ue) at AC - max | 
                                                500 V
                                             | 
| Switching hysteresis of Sn | 
                                                20 %
                                             | 
| Voltage measurement - max | 
                                                500 V
                                             | 
| Voltage measurement - min | 
                                                300 V
                                             | 
| Product category | 
                                                EMR Measuring and monitoring relays
                                             | 
| Terminal capacity | 
                                                2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule  1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid | 
| Threshold value | 
                                                Imbalance, Adjustable
                                             | 
| Voltage type of supply voltage | 
                                                AC
                                             | 
| Voltage type of operating voltage | 
                                                AC
                                             | 
| Rated switch current | 
                                                4 A
                                             | 
| Supply voltage at AC, 50 Hz - min | 
                                                300 V
                                             | 
| Supply voltage at AC, 50 Hz - max | 
                                                500 V
                                             | 
| Supply voltage at AC, 60 Hz - min | 
                                                300 V
                                             | 
| Supply voltage at AC, 60 Hz - max | 
                                                500 V
                                             | 
| Operating voltage at AC, 50 Hz - min | 
                                                300 V
                                             | 
| Operating voltage at AC, 50 Hz - max | 
                                                500 V
                                             | 
| Operating voltage at AC, 60 Hz - min | 
                                                300 V
                                             | 
| Operating voltage at AC, 60 Hz - max | 
                                                500 V
                                             |