Eaton Moeller series xEffect - PXS24 Electronic Protection Module. Electronic overcurrent protection for 24V DC, fix 16A with tripped signal out-, control in-put, w/o supply terminals
| Product Name |
Eaton Moeller series xEffect - PXS24 current monitoring relay
|
| Catalog Number |
PXS24S16A002
|
| UPC |
786689167592
|
| EAN |
9010238011281
|
| Product Length/Depth |
127 mm
|
| Product Height |
93 mm
|
| Product Width |
18 mm
|
| Product Weight |
0.118 kg
|
| Compliances |
CE
UL508 RoHS conform |
| Certifications |
EN45545-2
IEC 61373 |
| Features |
Green = OK; Red = Triggered
OFF = Channel not in operation Two-colored |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Plug-in connection
|
| Special features |
|
| Type |
Automation engineering 24V
|
| Amperage Rating |
16 A
|
| Voltage rating |
24 VDC (15 VDC - 30 VDC)
|
| Equipment heat dissipation, current-dependent |
2.9 W
|
| Mounting method |
Snap-fit on DIN rail (EN 60715)
|
| Degree of protection |
IP20
|
| Voltage type |
DC
|
| Busbar type |
LINE (+) and GND (-); max 60A in various lengths of up to 1m
|
| Number of channels |
1
|
| Terminal type |
Push in terminals
|
| Text field type |
17.5 mm x 6 mm
|
| Adjustable delay-on energization time - min |
0 s
|
| Adjustable off-delay time - min |
0 s
|
| Current measurement - max |
20.8 A
|
| Current measurement - min |
0 A
|
| Number of contacts (change-over contacts) |
0
|
| Number of contacts (normally closed contacts) |
0
|
| Number of contacts (normally open contacts) |
1
|
| Permitted delay-on energization time - max |
0 s
|
| Permitted off-delay time - max |
0 s
|
| Permitted storage and transport temperature - max |
100 °C
|
| Permitted storage and transport temperature - min |
-40 °C
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
| Rated control supply voltage (Us) at DC - max |
30 V
|
| Functions |
DC-voltage over current
|
| Rated control supply voltage (Us) at DC - min |
15 V
|
| Rated operational current (Ie) fix |
16 A
|
| Rated operational current for specified heat dissipation (In) |
16 A
|
| Trip time for electronic trip |
70 ms
|
| Ambient operating temperature details |
-30° C - 55° C
|
| Protection |
Electronic
|
| Capacitive load |
Up to 20,000 µF
|
| Output terminals |
3x LOAD (+) and 3x GND (-)
|
| Overload current and short-circuit current trip |
Type 1.3 x IN with active current limitation
|
| Terminal capacity |
2.5 mm² (flexible with ferrules)
4 mm² (rigid) |
| Type of current |
DC
|
| Voltage type of supply voltage |
DC
|
| Voltage type of operating voltage |
DC
|
| Rated switch current |
19 A
|
| Supply voltage at DC - min |
15 V
|
| Supply voltage at DC - max |
30 V
|
| Operating voltage at DC - min |
15 V
|
| Operating voltage at DC - max |
30 V
|