Download
RCD/MCB combination switch, 32A, 100mA, miniature circuit-br. type C trip characteristic, 1-ph+N, residual current circuit-br. trip characteristic: AC (PKNM-32/1N/C/01-MW)
| Product Name |
Eaton Moeller series xPole - PKN6/M RCBO - residual-current circuit breaker with overcurrent protection
|
| Catalog Number |
236306
|
| EAN |
4015082363062
|
| Product Length/Depth |
80 mm
|
| Product Height |
75 mm
|
| Product Width |
35 mm
|
| Product Weight |
0.204 kg
|
| Compliances |
RoHS conform
CE Marked |
| Product Type |
RCBO - Residual-current circuit breaker with overcurrent protection
|
| Model Code |
PKNM-32/1N/C/01-MW
|
| Application |
Switchgear for residential and commercial applications
|
| Basic function |
Combined RCD/MCB devices
|
| Number of poles |
Single-pole + N
|
| Number of poles (protected) |
1
|
| Number of poles (total) |
2
|
| Release characteristic |
C
|
| Rated current |
32 A
|
| Fault current rating |
0.1 A
|
| Type |
RCBO
|
| Voltage type |
AC
|
| Voltage rating |
230 V
|
| Frequency rating |
50 Hz
|
| Leakage current type |
AC
|
| Rated short-circuit breaking capacity (EN 60947-2) |
0 kA
|
| Surge current capacity |
0.25 kA
|
| Pollution degree |
2
|
| Width in number of modular spacings |
2
|
| Built-in depth |
70 mm
|
| Degree of protection |
IP20
|
| Rated operational current for specified heat dissipation (In) |
32 A
|
| Heat dissipation per pole, current-dependent |
0 W
|
| Equipment heat dissipation, current-dependent |
6.6 W
|
| Static heat dissipation, non-current-dependent |
0 W
|
| Heat dissipation capacity |
0 W
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| Current limiting class |
3
|
| Features |
Concurrently switching N-neutral
|