Photo is representative
Download
Eaton xComfort KLV LV systems Final Distribution Boards. Compact distribution board-flush mounting, Hybrid, 5-rows, 24MU, super-flat sheet steel door, 60UPS-HY24-SF
Product Name |
Eaton xComfort KLV hybrid distribution board
|
Catalog Number |
302431
|
EAN |
9010238161047
|
Product Length/Depth |
100 mm
|
Product Height |
840 mm
|
Product Width |
360 mm
|
Product Weight |
7.02 kg
|
Compliances |
RoHS conform
|
Certifications |
IEC/EN 60670-24 (PD)
IEC/EN 62208 |
Model Code |
KLV-60UPS-HY24-SF
|
Type |
Basic device
Installation distribution boards
KLV hybrid
|
Application |
Indoor
|
Color |
Traffic white (RAL 9016)
White |
Frequency rating of contacts |
50 Hz
|
Closure type |
Other
|
Enclosure material |
Plastic
|
Width in number of modular spacings |
12
|
Mounting method |
Flush mounted (plaster)
Flush mounting DIN-rail |
Material |
Sheet steel, powder-coated
Polystyren (plastic) |
Number of module space units per row |
12
|
Number of rows |
5
|
Terminal type |
Screw terminals
|
PE and N terminal number and cross section |
N: 13 x (0.75 mm² - 16 mm²)
N - Fi: 2 x (0.75 mm² - 16 mm²) + 2 x (0.75 mm² - 25 mm²) PE: 13 x (0.75 mm² - 16 mm²) |
Built-in depth |
80 mm
|
Built-in height |
0 mm
|
Built-in width |
0 mm
|
Internal depth |
80 mm
|
Cover/door color |
White
|
Cover/door model |
With notch
|
Cover/door type |
Door
Single |
Module rack type |
Rail frame / Media mounting plate
|
Protective shrouding material |
Plastic
|
Heat diss. ambient 35°C delta T:20°C flush mount individ. encl. top(IEC 60890) |
28 W
|
Ambient operating temperature details |
-5 °C - 40 °C
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
650 °C; meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Not relevant to indoor installations.
|
10.2.5 Lifting |
Does not apply to enclosures without lifting aids.
|
10.2.6 Mechanical impact |
IK05
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
IP30
|
10.4 Clearances and creepage distances |
Is the panel builder's responsibility.
|
10.5 Protection against electric shock |
Protection class 2, therefore not applicable.
|
10.6 Incorporation of switching devices and components |
Is the panel builder's responsibility.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Ui = 400 V AC
|
10.9.3 Impulse withstand voltage |
4 kV
|
10.9.4 Testing of enclosures made of insulating material |
Meets the product standard's requirements.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
Meets the product standard's requirements.
|
Fitted with: |
Neutral and protective conductor terminals with SK screw terminal technology
Door/Frame Device support rails Mounting plate Nail lugs Spirit level for leveling Cable retainer Device holder Front cover Installation instructions Microperforated mounting plate Imprintable sheet 1x single-way socket outlet Wall trough 3D adjustment element for mounting designed to adjust the mounting depth by up to 18 mm |
Functions |
Extension possible
Basic device |
Protection class |
II (totally insulated)
|
RAL-number |
9016
|
Special features |
IP30
Protection Class II
Plastic enclosure with sheet steel door, white (RAL 9016)
Note: To obtain protection class II, all devices installed on the mounting plate must be of the fully insulated type.
|
Used with |
Basic device
Installation distribution boards KLV hybrid |