Eaton Moeller® series E53 Proximity switch, capacitive, Sn=20mm, 1 N/C, 3L, NPN, M30, insulated material, M12
Product Name |
Eaton Moeller® series E53 Proximity switch
|
Catalog Number |
134810
|
EAN |
4015081316625
|
Product Length/Depth |
50.8 mm
|
Product Height |
137.16 mm
|
Product Width |
50.8 mm
|
Product Weight |
0.09 kg
|
Certifications |
IEC/EN 60947-5-2
CE |
Type |
Capacitive sensor
|
Electric connection type |
Plug-in connection
|
Enclosure material finishing |
Other
|
Fitted with: |
Status indication
|
Actuation type |
Other
|
Enclosure material |
Plastic
|
Enclosure type |
Cylinder, screw-thread
|
Category (EN 954-1) |
B
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Voltage type |
DC
|
Mounting method |
Flush mounting
|
Material |
Insulated material
|
Connection type |
3-wire
Plug-in connection M12 x 1 |
Installation type |
Concise
|
Degree of protection |
IP65
NEMA 4 NEMA 12 NEMA 13 |
Interface type |
None
|
LED indicator |
Status indication of Switching state: Red LED
|
Switch function type |
Breaker contact
|
Load current |
Max. 300 mA (Ie)
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
30 V
|
Rated control supply voltage (Us) at DC - min |
10 V
|
Rated switching distance (Sn) |
20 mm
|
Repeatability |
10 %
|
Sensor height |
0 mm
|
Sensor length |
80 mm
|
Supply voltage - max |
30 V
|
Supply voltage - min |
10 V
|
Switching hysteresis of Sn |
20 %
|
Voltage rating - max |
250 V
|
Width sensor |
0 mm
|
Product category |
E53 Capacitive Series
|
Residual ripple |
10 % (Uₑ)
|
Shock resistance |
30 g, Mechanical, Shock duration 11 ms
|
Switching frequency |
250 Hz
|
Switching output type |
NPN
|
Temperature drift of sn |
10 %
|
Safety performance level (EN ISO 13849-1) |
None
|
SIL (IEC 61508) |
None
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Diameter sensor |
30 mm
|
Number of contact energized outputs with signalling function |
0
|
Number of contacts (normally closed contacts) |
1
|
Number of outputs (protected contact energized) |
0
|
Number of outputs (protected semiconductor) |
0
|
Number of outputs (semiconductor with signaling function) |
1
|
Output current at protected output - max |
0 mA
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|