Eaton Moeller series TM Step switch, 10 A, Center mounting, 5 contact unit(s), Contacts: 9, Maintained, 0-3, Design: 8281
| Product Name |
Eaton Moeller® series TM Step switch
|
| Catalog Number |
046125
|
| EAN |
4015080461258
|
| Product Length/Depth |
122 mm
|
| Product Height |
30 mm
|
| Product Width |
30 mm
|
| Product Weight |
0.077 kg
|
| Certifications |
UL File No.: E36332
VDE 0660 UL CSA UL Category Control No.: NLRV CE CSA-C22.2 No. 14-05 IEC/EN 60947-5-1 CSA-C22.2 No. 94 UL 508 UL report applies to both US and Canada Certified by UL for use in Canada IEC/EN 60947 IEC/EN 60947-3 |
| Model Code |
TM-5-8281/EZ
|
| Fitted with: |
0 (off) position
Black thumb grip and front plate |
| Inscription |
0-3
|
| Number of poles |
Three-pole
|
| Degree of protection |
IP65
|
| Degree of protection (front side) |
IP65
NEMA 12 |
| Lifespan, mechanical |
1,000,000 Operations
|
| Mounting method |
Center mounting
|
| Mounting position |
As required
|
| Number of contact units |
5
|
| Operating frequency |
1200 Operations/h
|
| Overvoltage category |
III
|
| Pollution degree |
3
|
| Product category |
Control switches
|
| Product category |
Control switches
|
| Rated impulse withstand voltage (Uimp) |
4000 V AC
|
| Suitable for |
Front mounting
|
| Switching angle |
45 °
|
| Type |
Step switch
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
50 °C
|
| Ambient operating temperature (enclosed) - min |
-25 °C
|
| Ambient operating temperature (enclosed) - max |
40 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Terminal capacity (flexible with ferrule) |
1 x 1.0 mm², ferrules to DIN 46228
2 x 1.0 mm², ferrules to DIN 46228 |
| Terminal capacity (flexible) |
2 x 1.5 mm²
1 x 1.5 mm² |
| Terminal capacity (solid/flexible with ferrule AWG) |
14
|
| Terminal capacity (solid/stranded) |
2 x 1,5 mm²
1 x 1.5 mm² |
| Screw size |
M2.5, Terminal screw
|
| Tightening torque |
3.5 lb-in, Screw terminals
0.4 Nm, Screw terminals |
| Rated operating voltage (Ue) at AC - max |
500 V
|
| Rated operational current (Ie) at AC-21, 440 V |
10 A
|
| Rated operational power at AC-23A, 400 V, 50 Hz |
3 kW
|
| Rated uninterrupted current (Iu) |
10 A
|
| Uninterrupted current |
Rated uninterrupted current Iu is specified for max. cross-section.
|
| Short-circuit protection rating |
10 A gG/gL, Fuse, Contacts
|
| Switching capacity (main contacts, general use) |
10 A, Rated uninterrupted current max. (UL/CSA)
|
| Switching capacity (auxiliary contacts, general use) |
10A, IU, (UL/CSA)
|
| Switching capacity (auxiliary contacts, pilot duty) |
A300 (UL/CSA)
|
| Assigned motor power at 115/120 V, 60 Hz, 1-phase |
0.33 HP
|
| Assigned motor power at 115/120 V, 60 Hz, 3-phase |
0.75 HP
|
| Assigned motor power at 230/240 V, 60 Hz, 1-phase |
0.75 HP
|
| Assigned motor power at 230/240 V, 60 Hz, 3-phase |
1 HP
|
| Assigned motor power at 277 V, 60 Hz, 1-phase |
0.75 HP
|
| Control circuit reliability |
1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
|
| Number of contacts |
9
|
| Actuator function |
Maintained
With 0 (Off) position |
| Actuator type |
Toggle
|
| Number of steps |
3 (45°)
|
| Number of switch positions |
4
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0.15 W
|
| Rated operational current for specified heat dissipation (In) |
10 A
|
| Static heat dissipation, non-current-dependent Pvs |
0 W
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
UV resistance only in connection with protective shield.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|