Eaton Moeller series xPole - mRB64/M4 RCBO - residual-current circuit breaker with overcurrent protection. MCB/RCD, 10A, 300mA, MCB trip type B, 3p, RCCB trip type: A
| Product Name |
Eaton Moeller series xPole - mRB64/M4 RCBO - residual-current circuit breaker with overcurrent protection
|
| Catalog Number |
169598
|
| EAN |
4015081660919
|
| Product Length/Depth |
86 mm
|
| Product Height |
75 mm
|
| Product Width |
73 mm
|
| Product Weight |
0.43 kg
|
| Compliances |
CE Marked
RoHS conform |
| Certifications |
CE
|
| Model Code |
mRBM4-10/3/B/03-A-UK-PT
|
| Application |
Switchgear for residential and commercial applications
|
| Product range |
mRBM4-UK-PT
|
| Basic function |
Combined RCD/MCB devices
|
| Number of poles |
Three-pole
|
| Number of poles (protected) |
3
|
| Number of poles (total) |
3
|
| Tripping characteristic |
B
|
| Release characteristic |
B
|
| Amperage Rating |
10 A
|
| Rated current |
10 A
|
| Fault current rating |
0.3 A
|
| Sensitivity type |
Type A, pulse-current sensitive
|
| Type |
RCBO
|
| Voltage type |
AC
|
| Voltage rating |
230 V
|
| Rated operational voltage (Ue) - max |
415 V
|
| Rated insulation voltage (Ui) |
440 V
|
| Rated impulse withstand voltage (Uimp) |
4 kV
|
| Impulse withstand current |
Partly surge-proof, 250 A
|
| Frequency rating |
50 Hz
|
| Leakage current type |
A
|
| Rated switching capacity |
10 kA
|
| Rated switching capacity (IEC/EN 61009) |
10 kA
|
| Rated short-circuit breaking capacity (EN 60947-2) |
0 kA
|
| Rated short-circuit breaking capacity (EN 61009) |
10 kA
|
| Rated short-circuit breaking capacity (EN 61009-1) |
10 kA
|
| Rated short-circuit breaking capacity (IEC 60947-2) |
0 kA
|
| Surge current capacity |
250 kA
|
| Disconnection characteristic |
Undelayed
|
| Tripping |
Non-delayed
|
| Pollution degree |
2
|
| Width in number of modular spacings |
4
|
| Built-in depth |
69.5 mm
|
| Mounting Method |
DIN rail
|
| Degree of protection |
IP20
|
| Connectable conductor cross section (solid-core) - min |
1 mm²
|
| Connectable conductor cross section (solid-core) - max |
25 mm²
|
| Connectable conductor cross section (multi-wired) - min |
1 mm²
|
| Connectable conductor cross section (multi-wired) - max |
25 mm²
|
| Rated operational current for specified heat dissipation (In) |
10 A
|
| Heat dissipation per pole, current-dependent |
0 W
|
| Equipment heat dissipation, current-dependent |
7.6 W
|
| Static heat dissipation, non-current-dependent |
0 W
|
| Heat dissipation capacity |
0 W
|
| Ambient operating temperature - max |
40 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Current limiting class |
3
|