Eaton Moeller® series RS Non-contacting safety switch RS-Titan RS4-02-Q4
Product Name |
Eaton Moeller® series RS Safety switch
|
Catalog Number |
177298
|
EAN |
4015081717514
|
Product Length/Depth |
95 mm
|
Product Height |
13 mm
|
Product Width |
30 mm
|
Product Weight |
0.057 kg
|
Certifications |
ISO 14119
CE UL Listed EN ISO 13849 EN 62061 Certified by UL for use in Canada CSA File No.: UL report applies to both US and Canada UL Category Control No.: NRKH, NRKH7 UL File No.: E166051 |
Catalog Notes |
Reed contacts
|
Type |
Safety position switch
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Connector M12
|
Enclosure material finishing |
Plastic-coated
|
Enclosure material |
Plastic
|
Enclosure type |
Cuboid
|
Rated operational current (Ie) at DC-13, 125 V |
0 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0 A
|
Rated operational current (Ie) at DC-13, 24 V |
0.03 A
|
Sensor height |
13 mm
|
Sensor length |
52 mm
|
Width sensor |
26 mm
|
Product category |
Non-contacting safety switch
|
Action |
2020122120328-Mechanical Limit Switches.xlsm-Data
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-10 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
2
|
Number of contacts (normally open contacts) |
0
|
Number of safety auxiliary contacts |
2
|
Rated operational current (Ie) at AC-15, 125 V |
0 A
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
0 A
|
Rated operational current (Ie) at AC-15, 24 V |
0 A
|
Mounting position |
As required
|
Material |
Plastic
|
Degree of protection |
IP67
NEMA Other |
Interface type |
None
|
Terminal capacity (AWG) |
22
|
Relative humidity |
90 % (at 55 °C)
|
Rated operational voltage |
24 V DC
|
Repetition accuracy |
≤ 10 % (deviation)
|
Shock resistance |
30 g, Shock duration 11 ms, Half-Sinusoidal
|
Suitable for |
Safety functions
|
Vibration resistance |
0 - 2000 Hz, 1 mm
|
Safety parameter (EN ISO 13849-1) |
20,000,000 switching cycles, B10d
PL e, Performance level |
Safety parameter (IEC 62061) |
SIL: 3
|
Switching contact type |
Other
|