Eaton Moeller® series M22 Surface mounting enclosure, yellow, 1 mounting location
Product Name |
Eaton Moeller® series M22 Accessory Surface mounting enclosure
|
Catalog Number |
216536
|
EAN |
4015082165369
|
Product Length/Depth |
80 mm
|
Product Height |
56 mm
|
Product Width |
72 mm
|
Product Weight |
0.136 kg
|
Certifications |
CSA File No.: 012528
CE CSA-C22.2 No. 14-05 CSA-C22.2 No. 94-91 UL UL Category Control No.: NKCR IEC/EN 60947-5 UL File No.: E29184 UL 508 CSA CSA Class No.: 3211-03 |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
High-grade steel screws
|
Connection to SmartWire-DT |
No
|
Enclosure material |
Plastic
|
Enclosure type |
Surface mounting housing
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Force for positive opening - min |
0 N
|
Number of command positions |
1
|
Number of locations |
1
|
Enclosure color |
Yellow
|
Material quality |
Other
|
Opening diameter |
22.5 mm
|
RAL-number |
1004
|
Degree of protection |
NEMA 13
IP67/IP69K |
Knockouts |
2 x M16 (cable entry knockouts at the rear)
1 x M20 (cable entry knockout at the top) 2 x M20/25 (cable entry knockout at the side, 1 x each side) |