SmartPro 230V 1.5kVA 900W Line-Interactive UPS, Tower, LCD, USB, 8 Outlets
Product Name |
Eaton Tripp Lite series SmartPro UPS
|
Catalog Number |
SMX1500LCDT
|
UPC |
037332177445
|
Product Length/Depth |
19.3 in
|
Product Height |
11.3 in
|
Product Width |
9.1 in
|
Product Weight |
24.7 lb
|
Compliances |
CE Marked
RoHS SASO |
Certifications |
IEC/EN 62040-1
GoST-R IEC/EN 62040-2 |
Topology |
Line-interactive
|
Form factor |
Tower
|
Package contents |
|
Input nominal voltage |
230 VAC
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Receptacle |
C13
|
Output nominal voltage |
220V default(220/230/240V)
|
Electric current - max |
|
Battery replacement |
RBC51 (requires 2)
|
Runtime at half load |
9.96 min
|
Relative humidity |
0-95% non-condensing
|
Front Panel LCD Display |
LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutes
|
Output Receptacles |
C13
|
Product Highlights |
10 min. runtime at half load
8 C13 outlets—2 surge-only Monitoring of power conditions via PowerAlert software Corrects under- and overvoltages from 170V to 280V Interactive LCD monitoring screen |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
Nominal Output Voltage |
220V
230V 240V |
Network Management Cards Details |
Network management not supported
|
Output power factor |
0.6
|
Phase (input) |
Single-phase
|
Runtime at full load |
1.96 min. (900W)
|
Communication interface |
USB (HID enabled)
USB cabling included |
Dc Voltage |
24
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Communications Cable |
USB cabling included
|
Input Circuit Breakers |
10A fuse
|
High Voltage Transfer to Battery Power |
280V (factory setting), 275V (medium setting), 270V (narrow setting)
|
Low Voltage Transfer to Battery Power |
170V (factory setting), 175V (medium setting), 180V (narrow setting)
|
Undervoltage Correction |
Input voltages between 170 and 207 are boosted by 18%
|
Application |
|
Switch configuration |
Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test
|
Hot Swap PDU Options |
PDUBHV10 (2U / 8 C13 outlets)
|
AC suppression joule rating |
455
|
Output AC waveform (AC mode) |
Sine wave
|
Output AC waveform (battery mode) |
PWM sine wave
|
Output Capacity (kVA) |
1.5
|
Output Capacity (kW) |
0.9
|
Output Capacity (VA) |
1500
|
Output Capacity Details |
6.5 A @ 230 V~
|
Primary UPS Depth (mm) |
394
|
Primary UPS Height (mm) |
203
|
Primary UPS Width (mm) |
146
|
AC Suppression Response Time |
Instantaneous
|
Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch
|
Audible Alarms |
Audible alarm indicates power-failure and low-battery conditions
|
Battery Start Capability |
Cold-start operation supported
|
Cooling Method |
Fan
|
Frequency Rating Details |
Automatic frequency selection
|
Output Voltage Regulation (Line Mode) |
230V~ (+7% / - 12.8%)
|
Output Voltage Regulation(Battery Mode) |
+/- 5%
|
Overvoltage Correction |
Input voltages between 247 and 280 are reduced by 15%
|
Rechargeable Battery |
10.1 hours from 10% to 90%
|
Storage Temperature |
5° to 122°F (-15° to 50°C)
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
Nominal Voltage Details |
230V nominal output in battery mode
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Maximum Input Amps |
9
|
UPS Input Cord Length (m) |
1.8
|
UPS Power Module Dimensions |
8 x 5.75 x 15.5
|
Power Mode Transfer Time |
6 milliseconds
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
C14 inlet
|
Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out)
10/100Base T Ethernet |
UPS Output Receptacles |
6 UPS outlets, 2 surge-only outlets
|
High Availability UPS Features |
Automatic voltage regulation (AVR)
Hot swappable batteries Surge/noise protection |