Eaton S811 Soft starter, 66 A, 200 - 600 V AC, Us= 24 V DC, with control unit and pump algorithm, Frame size N
| Product Name |
Eaton S811 Soft starter
|
| Catalog Number |
168979
|
| EAN |
4015081654758
|
| Product Length/Depth |
163.9 mm
|
| Product Height |
174.5 mm
|
| Product Width |
67.5 mm
|
| Product Weight |
2.6 kg
|
| Certifications |
CCC
CE CSA Class No.: 3211-06, 2411-01 CSA22.2-14-1995 UL File No.: E202571 CSA CSA File No.: LR 353 UL IEC/EN 60947-4-2 UL Category Control No.: NMFT GB14048 CSA-C22.2 No. 14 UL 508 C-Tick |
| Type |
Soft starter for three-phase loads, with control unit and pump algorithm
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Fitted with: |
Internal bypass contacts
Internal bypass Motor overload protection Display |
| Pollution degree |
3
|
| Class |
Adjustable
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30 |
| Connection to SmartWire-DT |
No
|
| Rated impulse withstand voltage (Uimp) |
4000 V
|
| Frame size |
N
|
| Altitude |
Above 2000 m with 0.5 % derating per 100 m
Max. 2000 m |
| Number of inputs |
1 (current input)
|
| Ambient operating temperature - max |
50 °C
|
| Ambient operating temperature - min |
-30 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-50 °C
|
| Assigned motor power at 200/208 V, 60 Hz, 3-phase |
20 HP
|
| Assigned motor power at 220/230 V, 60 Hz, 3-phase |
20 HP
|
| Assigned motor power at 460/480 V, 60 Hz, 3-phase |
50 HP
|
| Assigned motor power at 600 V, 60 Hz, 3-phase |
60 HP
|
| Assigned motor power in-delta at 220/230 V, 60 Hz |
40 HP
|
| Assigned motor power in-delta at 460/480 V, 60 Hz |
75 HP
|
| Assigned motor power in-delta at 575/600 V, 60 Hz |
100 HP
|
| Equipment heat dissipation, current-dependent Pvid |
25 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Mains voltage - max |
600 V
|
| Mains voltage - min |
200 V
|
| Output voltage |
120 V AC/DC (relay outputs)
|
| Number of outputs |
2 Relay Outputs (programmable)
|
| Screwdriver size |
0.6 x 3.5 mm, Terminal screws, Control circuit cables
1.5 x 6 mm, Terminal screw, Main cables |
| Voltage type |
DC
|
| Rated operational voltage (Ue) - min |
200 V
|
| Rated power three-phase motor, inline, at 230 V |
18.5 kW
|
| Rated power three-phase motor, inline, at 400 V |
30 kW
|
| Rated power three-phase motor, inside delta, at 230 V |
30 kW
|
| Rated power three-phase motor, inside delta, at 400 V |
55 kW
|
| Static heat dissipation, non-current-dependent Pvs |
25 W
|
| Voltage rating - max |
600 V
|
| Application |
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact
|
| Mounting position |
As required
|
| Input current |
4 - 20 mA (Analog inputs)
|
| Drop-out voltage |
0 - 3 V, DC operated
|
| Overvoltage category |
II
|
| Degree of protection |
IP20
NEMA Other |
| Current consumption |
1000 mA, Control circuit, Regulator supply
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC 100 mA, Control circuit, Digital inputs, External 24 V (no-load) 150 mA, Control circuit, Digital inputs, External 24 V |
| Functions |
Suppression of DC components for motors
Overload monitoring Underload monitoring Single direction Soft start function Potential isolation between power and control sections Current limitation Suppression of closing transients Min. ramp time 1 s - fast switching (semiconductor contactor) |
| Delay time |
0 - 120 s, Soft start function, Ramp times
|
| Overload cycle |
AC-53a: 4.0 - 32: 99 - 3
|
| Drop-out time |
100 ms, DC operated
|
| Pick-up voltage |
21.6 - 26.4 V DC
|
| Radio interference class |
Class A (EN 55011)
|
| Fault memory |
10 Faults
|
| Pick-up time |
100 ms at DC
|
| Interfaces |
Modbus RTU (built-in)
|
| Kickstart |
Max. 2000 ms (Kickstart Duration)
100% (Kickstart voltage) |
| Rated control voltage (Uc) |
24 V DC
24 V DC (-10 %/+10 %) |
| Supply frequency |
50/60 Hz, fLN, Main circuit
|
| Terminal capacity (stranded) |
1 x (2.5 - 35) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables 2 x (1 - 2.5) mm², Control circuit cables |
| Rated control supply voltage (Us) at DC - max |
24 V
|
| Rated control supply voltage (Us) at DC - min |
24 V
|
| Rated insulation voltage (Ui) |
660 V
|
| Rated operational current (Ie) at AC-11 |
3 A
|
| Rated operational current (Ie) at AC-53 |
66 A
|
| Rated operational current (Ie) at AC-53, in-delta |
114 A
|
| Rated operational current for specified heat dissipation (In) |
66 A
|
| Rated operational power at 220/230 V, 50 Hz |
18.5 kW
|
| Rated operational power at 400 V, 50 Hz |
30 kW
|
| Rated operational power at 500 V, 50 Hz |
45 kW
|
| Rated operational power in-delta at 220/230 V, 50 Hz |
30 kW
|
| Rated operational power in-delta at 400 V, 50 Hz |
55 kW
|
| Rated operational power in-delta at 500 V, 50 Hz |
75 kW
|
| Rated operational voltage (Ue) - max |
600 V
|
| Ramp/run-up time |
360 s
|
| Shock resistance |
15 g, Mechanical
|
| Suitable for |
Branch circuits, not as BCPD, (UL/CSA)
|
| Tightening torque |
5.6 Nm (> 25 mm²)
4 Nm (≤ 6 mm²) 4.5 Nm (≤ 10 mm²) 0.4 Nm, Screw terminals, Control circuit cables 5 Nm (≤ 25 mm²) |
| Short-circuit protection rating |
NZMN1-S40, Type “1” coordination, Main conducting paths
|
| Start voltage |
Max. 85 %, Soft start function, Start voltage = turn-off voltage
|
| Startup class |
CLASS 30 (6 x Iₑ for 30 s)
CLASS 10 (star-delta replacement) CLASS 20 (heavy starting duty 3 x Iₑ for 45 s) |
| Terminal capacity (flexible with ferrule) |
1 x (2.5 - 35) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables 2 x (1 - 2.5) mm², Control circuit cables |
| Terminal capacity (solid) |
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables 1 x (2.5 - 35) mm², Main cables |
| Terminal capacity (solid/stranded AWG) |
1 x (14 - 12), Control circuit cables
1 x (14 - 2), Main cables 2 x (14 - 12), Control circuit cables |