Reset
Eaton Moeller series xEffect - FRBm6/M RCBO - residual-current circuit breaker with overcurrent protection. RCD/MCB, 4A, 10mA, MCB trip type C, 1-phase+N, RCCB trip type: AC
Product Name |
Eaton Moeller series xEffect - FRBm6/M RCBO - residual-current circuit breaker with overcurrent protection
|
Catalog Number |
170980
|
EAN |
4015081671045
|
Product Length/Depth |
80 mm
|
Product Height |
75 mm
|
Product Width |
35 mm
|
Product Weight |
0.205 kg
|
Compliances |
CE Marked
RoHS conform |
Certifications |
CE
EN45545-2 IEC 61373 |
Basic function |
Combined RCD/MCB devices
|
Number of poles (total) |
2
|
Type |
RCBO
|
Application |
Switchgear for industrial and advanced commercial applications
|
Tripping characteristic |
C
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
Sensitivity type |
AC current sensitive
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
Sensitivity type |
AC current sensitive
|
Type |
RCBO
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
Operating ambient temperature - min |
-25 °C
|
Operating ambient temperature - min |
-25 °C
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
Impulse withstand current |
Partly surge-proof, 250 A
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
Release characteristic |
C
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
Current limiting class |
3
|
Rated switching capacity (IEC/EN 61009) |
10 kA
|
Rated short-circuit breaking capacity (EN 60947-2) |
15 kA
|
Disconnection characteristic |
Undelayed
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
Width in number of modular spacings |
2
|
Heat dissipation capacity |
0 W
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
Pollution degree |
2
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
Built-in depth |
75.5 mm
|
Surge current capacity |
0.25 kA
|