Eaton Moeller® series M22 AS-Interface module, 2I, 1Q, spring clamp connection
Product Name |
Eaton Moeller® series M22 Accessory AS-Interface connection
|
Catalog Number |
231271
|
EAN |
4015082312718
|
Product Length/Depth |
40 mm
|
Product Height |
30 mm
|
Product Width |
40 mm
|
Product Weight |
0.017 kg
|
Certifications |
CSA-C22.2 No. 94-91
DIN EN 50295 IEC/EN 60947 UL File No.: E29184 CSA Class No.: 3211-03 UL IEC/EN 60947-5 UL Category Control No.: NKCR CSA File No.: 012528 UL 508 CSA-C22.2 No. 14-05 CSA CE |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Addressing |
Adress set via connection to AS-Interface cable
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Connection to SmartWire-DT |
No
|
Bezel color |
Titanium
|
Output voltage |
24 V DC (-15/+10 %)
|
Mounting position |
As required
|
Output |
1 (normally 19 V/8 mA) Output, protected against short-circuit
Output for 1 LED element: M22-LED-... |
Connection type |
Base fixing for RMQ-Titan
|
Cable length |
2 m connection cable
|
Degree of protection |
IP00
|
Power consumption |
40 mA
|
Protocol |
AS-Interface (S-3.A.E)
|
Number of modules |
62 (Suconet-K)
|
Radio interference class |
EN 55011
EN 55022 |
Rated operational voltage |
26.5 - 31.6 V DC (AS-Interface specification)
|
Shock resistance |
30 g, Mechanical, Shock duration 11 ms
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-25 °C
|
Built-in diameter |
0 mm
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
No-load current |
30 A
|
Input |
2 Inputs (22 V/5 mA, protected against short-circuit)
Inputs for 2 contacts |
Interfaces |
2.1 (Output specification)
|
LED indicator |
Status indication of POWER AS-Interface cable in the switch front: Green LED on the board
Status indication of ERROR AS-Interface, AS-Interface Master failure in the switch front: Red LED on the board |
Number of appliances to build in |
0
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
1.3 W
|
Product category |
Accessories
|
Protection |
AS-Interface protected against polarity reversal
|