Download document () of 20

118705
Model code: ESR5-NV3-30

Eaton ESR5 Safety relay emergency stop/protective door/light curtain, 24 V DC, 4 enabling paths(2del.)

General specifications

Product Name
Eaton ESR5 Safety relay
Catalog Number
118705
Model Code
ESR5-NV3-30
EAN
4015081168453
Product Length/Depth
114.5 mm
Product Height
99 mm
Product Width
22.5 mm
Product Weight
0.171 kg
Certifications
EN ISO 13849-1
CE
CSA Class No.: 3211-83; 3211-03
IEC 61508, Parts 1-7
UL File No.: E29184
UL 508
UL report applies to both US and Canada
IEC/EN 60204
EN 50178
Certified by UL for use in Canada
IEC 62061
2014/30/EU
CSA-C22.2 No. 14-95
UL Category Control No.: NKCR; NKCR7
UL
Machines 2006/42/EG

Feature & Functions

Electric connection type
Screw connection
Features
Automatic start
Manual start
Basic insulation
2 Non-delayed enable current paths
Fitted with:
Approval for TÜV
Start input
Selectable cross-circuit detection
Detachable clamps
Feedback circuit
Approval according to UL
Functions
1-channel
2-channel
Time function
Material
Contacts: silver tin oxide, gold plated (AgSnO2, 0.2 µm Au)
Enclosure: Polyamide (PA), not reinforced

General information

Connection type
M3 screw terminals
Current consumption
75 mA, DC
Degree of protection
Terminals: IP20
IP20
Installation location: ≥ IP54
Enclosure: IP20
Duty factor
100 %
Emitted interference
According to EN 61000-6-4
Interference immunity
According to EN-61000-6-2
According to EN 662061_x
LED indicator
Status indication of SmartWire-DT network: Green LED
Lifespan, mechanical
10,000,000 Operations
Lifetime
240 month
Model
Basic device
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Mounting width
22.5 mm
Overvoltage category
III
Pollution degree
2
Power loss
Normally 7.8 W
Product category
Electronic safety relays
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
4000 V AC
Recovery time
330 ms (restart)
Safety performance level (EN ISO 13849-1)
Level e
Safety parameter (IEC 62061)
SIL 3 only for high demand requirements, Safety integrity level
Cat. 4, Category
18 x 10-10, PFHd, Probability of failure per hour
SIL 3, Safety integrity level
SILCL 3, Safety integrity level claim limit
SIL 3, Safety integrity level, In accordance with IEC 61508
Stop category (IEC 60204)
0
1
Suitable for
Monitoring of position switches
Module used to safely interrupt electrical circuits
Safety relay for monitoring emergency stop and protective door switch
Monitoring of optoelectronic protection equipment
Monitoring of emergency-stop circuits
Safety position switch with mechanical securing action LS-S…MT-ZBZ
Switching frequency
Max. 0.5 Hz, Input data
Type
  • Emergency stop category 1; emergency switching off
  • Feedback circuit
  • Light curtain
  • Protective door
Voltage type
DC

Ambient conditions, mechanical

Mounting position
As required
Prooftest
240 Months (High Demand)
Switching capacity
3 A at 3600 O/h, DC-13 at 24 V, Outputs
5 A at 3600 O/h, AC-15 at 230 V, Outputs
0.4 W
In accordance with IEC 60947-5-1, Outputs
Vibration resistance
10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Altitude
Max. 2000 m
Ambient operating temperature - min
-20 °C
Ambient operating temperature - max
45 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3
Cold to EN 60068-2-1
Environmental conditions
Clearance in air and creepage distances according to EN 60947-1, UL 508, CSA C22.2, No. 14-95
Condensation: Non-condensing
Operating temperature - min
-20 °C
Operating temperature - max
45 °C
Relative humidity
< 75 %

Terminal capacities

Terminal capacity
2 x (0.2 – 1) mm², solid
24 - 12 AWG, solid or stranded
1 x (0.2 – 2.5) mm², solid
2 x (0.25 – 1) mm², flexible with ferrule
1 x (0.25 – 2.5) mm², flexible with ferrule
Stripping length (main cable)
7 mm
Screwdriver size
0.6 x 3.5 mm, Terminal screws
2, Terminal screw, Pozidriv screwdriver
Tightening torque
0.6 Nm, Screw terminals

Electrical rating

Inrush current
0.025 - 6 A
Power supply circuit
1.8 W (DC operated)
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
26.4 V
Rated control supply voltage (Us) at AC, 60 Hz - min
20.4 V
Rated control supply voltage (Us) at AC, 60 Hz - max
26.4 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
24 V
Rated insulation voltage (Ui)
250 V
Rated operational voltage
24 V DC (power supply)
Approx. 24 V DC at input, starting and feedback circuit
230 V AC
Short-circuit current
0.1 A, Input data
Short-circuit protection
Fuse 10 A gL/gG NEOZED, For output circuits, External
Short-circuit protection rating
10A gL/gG, NEOZED (N/O), Output fuse, External, Output data
6A gL/gG, NEOZED (N/C), Output fuse, External, Output data

Input/Output

Breaking power
144 W max., resistive load (τ = 0 ms), at 24 V DC
42 W max., inductive load (τ = 40 ms), at 24 V DC
88 W max., resistive load (τ = 0 ms), at 220 V DC
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
23 W max., inductive load (τ = 40 ms), at 220 V DC
288 W max., resistive load (τ = 0 ms), at 48 V DC
33 W max., inductive load (τ = 40 ms), at 48 V DC
25 W max., inductive load (τ = 40 ms), at 110 V DC
90 W max., resistive load (τ = 0 ms), at 110 V DC
Input
∞ ms, Simultaneity for inputs 1/2
Nominal current
3.5 A
Number of inputs
One- and two-channel
Number of outputs (safety related, delayed) with contact
2
Number of outputs (safety related, undelayed) with contact
2
Number of outputs (signaling function, delayed) with contact
0
Number of outputs (signaling function, undelayed) with contact
0
Off-delay
0.1 - 30 s (± 40 %, K3, K4 adjustable)
Permissible total cable resistance
500 Ω (input and starting circuits for UN)
Pick-up time
150 ms typ. (at Uₑ in automatic mode)
150 ms typ. (controlled start, K1, K2 - for UN manual operation)
150 ms typ. (controlled start, K1, K2 - for UN automatic mode)
150 ms typ. (at Uₑ in manual mode)
Quadratic summation current
55 A² (ITH² = I1² + I2² + I3² + I4² + I5²)
Reset time
Normally 100 ms (delayed contacts)
20 ms (non-delayed contacts)
Resistance
500 Ω (impedance)
Switching voltage
250 V
Uninterrupted current
6 A N/O, Limiting continuous current
6 A N/C, Limiting continuous current

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
7.8 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.