Eaton Moeller series NZM - Molded Case Circuit Breaker. Bowden cables, L=1000mm
Product Name |
Eaton Moeller series NZM mounting accessory
|
Catalog Number |
281587
|
Model Code |
NZM-XBZ1000
|
EAN |
4015082815875
|
Product Length/Depth |
200 mm
|
Product Height |
50 mm
|
Product Width |
200 mm
|
Product Weight |
0.138 kg
|
Compliances |
UL/CSA
IEC RoHS conform |
Certifications |
UL489
CSA-C22.2 No. 5-09 CSA (File No. 22086) UL (Category Control Number DIHS) CSA (Class No. 1437-01) UL (File No. E140305) UL listed CE marking CSA certified IEC60947 |
Used with |
NZM1(-4), PN1(-4), N(S)1(-4)
PN2 PN2-4 PN1 NS1 NZM2(-4), PN2(-4), N(S)2(-4) NZM4-4 PN1-4 N2 N3-4 NZM3(-4), PN3(-4), N(S)3(-4) N1 N4-4 NS3 NS4 NZM1-4 NZM2 PN3-4 N1-4 N3 N4 NS2 NZM1 NZM3 NZM4 NZM4(-4), N(S)4(-4) PN3 N2-4 NZM2-4 NZM3-4 |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Frame |
NZM1/2/3/4
|
Accessory/spare part type |
Other
|
Type |
Accessory. Mechanical interlock
|
Special features |
For mechanical interlocking of (door coupling) rotary handles
|