Eaton Moeller series xEffect - FAZ-NA, FAZ-RT MCB. Miniature circuit breaker (MCB), 6 A, 4p, characteristic: D, NA
| Product Name |
Eaton Moeller series xEffect - FAZ-NA, FAZ-RT MCB
|
| Catalog Number |
190831
|
| Product Length/Depth |
105 mm
|
| Product Height |
75.5 mm
|
| Product Width |
70.8 mm
|
| Product Weight |
0.478 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC 60947-2
CSA-C22.2 No. 5-09 CSA (Class No. 1432-01) Specially designed for North America, suitable as BCPD UL 489 CSA (File No. 204453) North America (UL listed, CSA certified) UL (File No. E235139) UL (Category Control Number DIVQ) CE marking IEC/EN 60947-2 UL 489, CSA C22.2 No. 5 EN45545-2 IEC 61373 |
| EAN |
4015081904785
|
| Model Code |
FAZ-D6/4-NA
|
| Accessories required |
Z-IHK-NA 113895
|
| Current limiting class |
3
|
| Features |
Additional equipment possible
|
| Fitted with: |
Z-IS/SPE-1TE 274418
|
| Functions |
Current limiting circuit breaker
|
| Internal resistance at room temperature (single-pole, 50 Hz) |
32 mΩ
|
| Special features |
|
| Suitable for |
Flush-mounted installation
|
| Used with |
FAZ-XAA-NA110-415V AC 102036 (Shunt trip release)
FAZ-XAA-NA12-110V AC 102037 (Shunt trip release)
FAZ-NA Miniature circuit breaker FAZ-XAA-NA110-415V AC 102036 (Shunt trip release) FAZ-XAA-NA12-110V AC 102037 (Shunt trip release) |
| Amperage Rating |
6 A
|
| Application |
|
| Number of poles |
Four-pole
|
| Number of poles (protected) |
4
|
| Number of poles (total) |
4
|
| Release characteristic |
D
|
| Tripping characteristic |
D
|
| Type |
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Ambient operating temperature - max |
75 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature (UL) - max |
40 °C
|
| Ambient operating temperature (UL) - min |
-5 °C
|
| Heat dissipation capacity |
0 W
|
| Heat dissipation per pole, current-dependent |
0 W
|
| Rated operational current for specified heat dissipation (In) |
6 A
|
| Static heat dissipation, non-current-dependent |
0 W
|
| Admissible back-up fuse - max |
125 A gL/gG
|
| Direction of incoming supply |
As required
|
| Frequency rating - max |
60 Hz
|
| Frequency rating - min |
50 Hz
|
| Lifespan, electrical |
min. 1500 operations
min. 6000 operations (UL) |
| Operational switching capacity |
7.5 kA
|
| Overvoltage category |
III
|
| Pollution degree |
2
|
| Rated impulse withstand voltage (Uimp) |
4 kV
|
| Rated insulation voltage (Ui) |
440 V
|
| Rated operational voltage (Ue) - max |
240 V
|
| Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V |
10 kA
|
| Rated short-circuit breaking capacity (IEC/EN 60898-1)- Icn at 400 V |
15 kA
|
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V |
10 kA
|
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V |
14 kA
|
| Rated switching capacity (IEC/EN 60947-2) |
15 kA
|
| Selectivity class |
3
|
| Voltage rating |
277 V AC / 480 V AC
|
| Voltage rating (IEC/EN 60947-2) |
415 V
|
| Voltage rating (UL) |
480Y/277 V
|
| Voltage rating at DC |
60 V DC
|
| Voltage type |
AC
|
| Built-in depth |
60 mm
|
| Connectable conductor cross section (multi-wired) - max |
25 mm²
|
| Connectable conductor cross section (multi-wired) - min |
1 mm²
|
| Connectable conductor cross section (solid-core) - max |
25 mm²
|
| Connectable conductor cross section (solid-core) - min |
1 mm²
|
| Contact position indicator color |
Red / green
|
| Degree of protection |
IP40 (when fitted)
UL/CSA Type: - IP20 (IEC) IP20 |
| Enclosure width |
105 mm
|
| Frame |
45 mm
|
| Lifespan, mechanical |
10000 operations
|
| Mounting Method |
Top-hat rail IEC/EN 60715
|
| Mounting position |
As required
|
| Mounting width |
17.7 mm
|
| Mounting width per pole |
17.7 mm
|
| Terminal capacity (control cable) |
25 mm² (1x)
|
| Terminal capacity of screw terminals for main cable |
10 mm² (2x)
|
| Terminal protection |
Finger and hand touch safe, DGUV VS3, EN 50274
|
| Terminals (top and bottom) |
Lift terminal / ring-tongue
|
| Tightening torque |
UL: 4 Nm (36 lb-in) for AWG 6
UL: 2.8 Nm (25 lb-in) for AWG 10 - AWG 8 Max. 2.4 Nm UL: 2.4 Nm (21 lb-in) for AWG 18 - AWG 12 |
| Width in number of modular spacings |
4
|