Eaton DG1 Variable frequency drive, 400 V AC, 3-phase, 310 A, 160 kW, IP00, Brake chopper, DC link choke
Product Name |
Eaton DG1 variable frequency drive
|
Catalog Number |
3-4917-102A
|
EAN |
4015081941629
|
Product Length/Depth |
561 mm
|
Product Height |
1538 mm
|
Product Width |
506 mm
|
Product Weight |
410 kg
|
Certifications |
UL Category Control No.: NMMS, NMMS7
CUL EAC CE UL Safety requirements: IEC/EN 61800-5 UkrSEPRO C-Tick Specification for general requirements: IEC/EN 61800-2 RoHS, ISO 9001 UL File No.: E134360 IEC/EN 61800-3 |
Model Code |
DG1-34310FB-C00C
|
Features |
Temperature-controlled fan
Externally accessible fan |
Functions |
4-quadrant operation possible
|
Air volume capacity |
1400 m³/h
|
Cable length |
C3 ≤ 50 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length 50 m, screened, maximum permissible, Motor feeder |
Degree of protection |
IP00
NEMA Other |
Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
Environmental class |
3C2, 3S2 (Air quality)
|
Fitted with: |
DC link choke
Additional PCB protection Brake chopper IGBT inverter Multi-line graphic display Radio interference suppression filter Internal DC link Breaking resistance Control unit PC connection |
Frame size |
FS7
|
Mounting position |
Vertical
|
Number of slots |
2 (expansion)
|
Overvoltage category |
III
|
Pollution degree |
2
|
Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
Radio interference class |
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. C1: with external filter, for conducted emissions only |
Safety function/level |
STO (Safe Torque Off, SIL1, PLc Cat 1)
|
Shock resistance |
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27 |
Suitable for |
Branch circuits, (UL/CSA)
|
Vibration |
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak) |
Altitude |
Max. 1000 m
Above 1000 m with 1 % derating per 100 m Max. 3000 m Max. 2000 m for Corner Grounded TN Systems |
Ambient operating temperature - min |
-10 °C
|
Ambient operating temperature - max |
50 °C
|
Ambient operating temperature at 150% overload - min |
-10 °C
|
Ambient operating temperature at 150% overload - max |
40 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
70 °C
|
Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
Current limitation |
0.1 - 2 x IH (CT), motor, main circuit
|
Efficiency |
97.9 % (η)
|
Input current ILN at 110% overload |
385 A
|
Input current ILN at 150% overload |
311 A
|
Mains current distortion |
28 %
|
Mains switch-on frequency |
Maximum of one time every 60 seconds
|
Mains voltage - min |
380 V
|
Mains voltage - max |
500 V
|
Operating mode |
Sensorless vector control (SLV)
Speed control with slip compensation U/f control Torque regulation |
Output frequency - min |
0 Hz
|
Output frequency - max |
400 Hz
|
Output voltage (U2) |
400 V AC, 3-phase
480 V AC, 3-phase 500 V AC, 3-phase |
Overload current IL at 110% overload |
423.5 A
|
Overload current IL at 150% overload |
465 A
|
Rated conditional short-circuit current (Iq) |
65 kA
|
Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
Rated frequency - min |
45 Hz
|
Rated frequency - max |
66 Hz
|
Rated operational current (Ie) at 110% overload |
385 A
|
Rated operational current (Ie) at 150% overload |
310 A
|
Rated operational power at 380/400 V, 50 Hz |
160 kW
|
Rated operational power at 380/400 V, 50 Hz, 110% overload |
200 kW
|
Rated operational power at 500 V, 50 Hz |
200 kW
|
Rated operational power at 500 V, 50 Hz, 110% overload |
250 kW
|
Rated operational voltage |
480 V AC, 3-phase
400 V AC, 3-phase 500 V AC, 3-phase |
Resolution |
0.01 Hz (Frequency resolution, setpoint value)
|
Short-circuit protection rating |
500 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
Starting current - max |
200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section
|
Supply frequency |
50/60 Hz
|
Switching frequency |
2 kHz, 1.5 - 6 kHz adjustable, fPWM, Power section, Main circuit
|
System configuration type |
TN-S, TN-C, TN-C-S, TT, IT
|
Voltage rating - max |
500 VAC
|
Assigned motor current IM at 400 V, 50 Hz, 110% overload |
353 A
|
Assigned motor current IM at 400 V, 50 Hz, 150% overload |
283 A
|
Assigned motor current IM at 440 - 480 V, 60 Hz, 150% overload |
302 A
|
Assigned motor current IM at 440/480 V, 60 Hz, 110% overload |
361 A
|
Assigned motor current IM at 500 V, 50 Hz, 110% overload |
349 A
|
Assigned motor current IM at 500 V, 50 Hz, 150% overload |
279 A
|
Assigned motor power at 460/480 V, 60 Hz |
250 HP
|
Assigned motor power at 460/480 V, 60 Hz, 110% overload |
300 HP
|
Apparent power at 400 V |
266.7 kVA
|
Apparent power at 480 V |
333.4 kVA
|
Braking resistance |
1.4 Ω
|
Braking torque |
Adjustable to 150 % (I/Ie), DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit Max. 30 % MN, Standard - Main circuit Adjustable to 150 %, DC - Main circuit |
Switch-on threshold for the braking transistor |
850 VDC
|
Number of inputs (analog) |
2
|
Number of inputs (digital) |
8
|
Number of outputs (analog) |
2
|
Number of outputs (digital) |
1
|
Number of relay outputs |
3 (parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 V AC) / 6 A (24 V DC))
|
Rated control voltage (Uc) |
24 V DC (external, max. 250 mA options incl.)
|
Communication interface |
CANopen®, optional
Modbus RTU, built in DeviceNet, optional PROFIBUS, optional Ethernet IP, built in SmartWire-DT, optional Modbus TCP, built in BACnet MS/TP, built in |
Connection to SmartWire-DT |
Yes
In conjunction with DXG-NET-SWD SmartWire DT module |
Protocol |
BACnet
CAN DeviceNet EtherNet/IP MODBUS Other bus systems PROFIBUS PROFINET IO TCP/IP |
Equipment heat dissipation, current-dependent Pvid |
5465 W
|
Rated operational current for specified heat dissipation (In) |
310 A
|
Static heat dissipation, non-current-dependent Pvs |
108 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|