Download document () of 20

How buildings are used and the perceived risks within buildings are changing. As a result of this there are ongoing changes in legislative requirements in the design and selection of new innovative solutions which protect occupants not just in the short term but for the full expected design life of the building. There are many discussions to be had or perceptions of what things really mean within this critical subject but here we will review a few that we feel are important to helping build a safer future.

In this chapter of Eaton's online knowledge journey we’ll review the following key topics.

Please note all of the following webinars are CPD accredited.

CPD accreditation logo UK
 
building-under-construction

Building a safer future – New UK building regulations

Recording available on-demand: click here

Speaker: Marc Gaunt

Overview: In this webinar we'll provide an overview of the likely impact on construction in the short and long term following the governments workplan proposal announced in spring.

In the wake of the Grenfell Fire disaster and the publication of "Building a Safer Future’ in the summer of 2019, a consultation was opened on proposed recommendations for UK construction. In spring 2020 UK government announced its workplan for a full technical review of Approved Document B (fire safety guidance in the building regulations) and proposed actions from Building a Safer Future.

In this webinar we'll provide an overview of the likely impact on construction in the short and long term.
spacer
 

Selection & design of Emergency Lighting – Central Power Supplies

Recording available on-demand: click here

Speaker: Darren Harper & Marc Gaunt

Overview: In this webinar we’ll explain how the Central Power Supply works and the benefits. The types of systems and their applications, as well as the preferred code of practice for Central Power Supplies and the testing / maintenance requirements.

office building
For specification of a central power supply for emergency lighting purposes, consideration must be given to the primary function required and regulatory requirements of the application. There are numerous types of central power supplies available on the market for various applications, so it is essential that when selecting a system for Emergency Lighting it meets all mandatory requirements and the obligations to ensure sufficient life safety within buildings. 

In this webinar we’ll explain how the Central Power Supply works and the benefits. The types of systems and their applications, as well as the preferred code of practice for Central Power Supplies and the testing / maintenance requirements.
spacer
 
Engineering diagram blueprint paper drafting project sketch architectural. industrial drawing detail and several drawing tools

Principles of good Emergency Lighting

Recording available on-demand: click here

Speaker: Anthony Martindale, Harry Russell & Darren Harper

Overview: In this webinar we’ll help you to understand the principles of good Emergency Lighting (EL) including requirements in accordance to the standards, EL designs and comparison of alternative EL systems.

The selection and design of an emergency lighting (EL) system is vital, so that it meets all the relevant application design standards and legislative needs. Whether you’re an experienced engineer or building your experience in EL during this webinar we'll help you to understand the principles of good EL including: - An overview of the requirements of BS5266 - How to design an emergency lighting scheme - Open area and escape route requirements - Requirements for exit signs - Data authentication and the importance of quality - Comparing alternative types of emergency lighting and the use of automatic testing - Designing emergency lighting installations.
spacer
 

AFDDs – Dispelling the myths

Recording available on-demand: click here

Speaker: Marc Gaunt & Giuseppe Sgro

Overview: In this webinar we'll recap on the recommendations set out in the 18th Edition wiring regulations,  dispel some of the myths associated with the technology, provide practical examples of applications and an insight on the trajectory of future regulations.

Family in front of modern residential apartment buildings
The 18th Edition of the UK Wiring Regulations BS7671 saw the introduction of a number of new recommendations associated with the use of AFDD (Arc Fault Detection Devices).

In this webinar we'll recap on the recommendations, dispel some of the myths associated with the technology, provide practical examples of applications and an insight on the trajectory of future regulations.
spacer
 
Eaton xEnergy Main

Electrical safety in LV switchboards

Recording available on-demand: click here

Speaker: Tariq Hussain, Adam Tennant & Drew Clough

Overview: In this webinar we’ll take a deeper dive in to the forms of separation according to EN 61439 and new, supplementary solutions & technologies to increase electrical safety for operators even further and mitigate the risks of Arc Flash.

For specifiers, one of the most significant choices they face when specifying a low-voltage assembly, is the form of separation. Selection of an inappropriate form of separation may mean the assembly is over specified meaning a much more expensive solution than required, or more concerning underspecified therefore not providing adequate levels of safety for the intended application.

In this webinar we’ll take a deeper dive in to the forms of separation according to EN 61439 and new, supplementary solutions and technologies to increase electrical safety for operators even further and mitigate the risks of Arc Flash.
spacer