Photo is representative
                                
                                
                                    
                                    Download
                                
                                
                                Eaton Moeller series NZM - Molded Case Circuit Breaker. Main switch assembly kit, on the right side, red, size 1
| Product Name | 
                                                Eaton Moeller series NZM operating element
                                             | 
| Catalog Number | 
                                                266656
                                             | 
| EAN | 
                                                4015082666569
                                             | 
| Product Length/Depth | 
                                                190 mm
                                             | 
| Product Height | 
                                                100 mm
                                             | 
| Product Width | 
                                                100 mm
                                             | 
| Product Weight | 
                                                0.881 kg
                                             | 
| Compliances | 
                                                UL/CSA  IEC RoHS conform | 
| Certifications | 
                                                CSA-C22.2 No. 5-09  CSA (Class No. 1437-01) UL (File No. E140305) UL (Category Control Number DIHS) CSA certified CSA (File No. 22086) UL489 CE marking IEC60947 UL listed | 
| Model Code | 
                                                NZM1-XSR-R
                                             | 
| Used with | 
                                                N(S)1(-4)  NZM1(-4) PN1(-4) | 
| Features | 
                                                Red-yellow for emergency switching off  Lockable Actuation of the switch on the control panel side wall Switch mounting on mounting plate | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Color | 
                                                Red
                                             | 
| Fitted with: | 
                                                Extension shaft  Door coupling rotary handle NZM...-XV4 extension shaft Black and yellow lightning symbol External warning plate/marking plate in German/English Padlock | 
| Frame | 
                                                NZM1
                                             | 
| Activation type | 
                                                Actuation on the right
                                             | 
| Suitable for | 
                                                Switch disconnector  Power circuit breaker Emergency stop | 
| Cover/door type | 
                                                Door interlock lockable in the 0 position using up to 3 padlocks on the handle
                                             | 
| Type | 
 | 
| Special features | 
 | 
| Degree of protection / NEMA enclosure type | 
                                                IP66  4X. 12 |