Eaton XN Base module washer XI/ON, tension spring, 3 connection levels, con. to C rail
Product Name |
Eaton XN Rack
|
Catalog Number |
140079
|
EAN |
7640130121164
|
Product Length/Depth |
117.6 mm
|
Product Height |
49.9 mm
|
Product Width |
12.6 mm
|
Product Weight |
0.031 kg
|
Certifications |
UL Recognized
Certified by UL for use in Canada Rated data for terminations according to IEC/EN 60947-7-1 IEC/EN 6113-2 CE UL Category Control No.: NRAQ, NRAQ7 IEC/EN 61000-6-2 IEC/EN 61000-6-4 CSA-C22.2 No. 142 IEC/EN 61131-2 UL 508 UL report applies to both US and Canada CSA Class No.: 2252-01, 2252-81 UL File No.: E205091 CE, cUL |
Fitted with: |
Pluggable modules, digital I/O
Power supply Pluggable modules, central modules |
Degree of protection |
IP20
|
Mounting method |
Rail mounting possible
|
Number of connection levels |
3
|
Type |
XI/ON slice card base module
|
Used with |
XN-2DO-120/230VAC-0.5A
XN-2DO-24VDC-0.5A-P XN-2DO-24VDC-2A-P XN-2DO-24VDC-0.5A-N |
Voltage type |
DC
|
Drop and topple |
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
|
Shock resistance |
Mechanical, According to IEC/EN 60068-2-27
Continuous according to IEC/EN 60068-2-29 |
Vibration resistance |
According to IEC/EN 60068-2-6
|
Ambient operating temperature - min |
0 °C
|
Ambient operating temperature - max |
55 °C
|
Environmental conditions |
Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation)
Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation) |
Relative humidity |
5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
|
Air discharge |
Air/contact discharge according to IEC/EN 61000-4-2
|
Burst impulse |
According to IEC/EN 61000-4-4
|
Electromagnetic fields |
According to IEC EN 61100-4-2
|
Emitted interference |
230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3)
30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3) |
Radiated RFI |
IEC/EN 61100-4-6
|
Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
Voltage dips |
According to EN 61131-2 (Voltage fluctuations/voltage dips)
|
Terminal capacity |
0.5 - 2.5 mm², solid, H07V-U
0.5 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) 0.5 - 1.5 mm², flexible without ferrule, H07V-K 0.5 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
Gauge pin |
A1 (according to IEC/EN 60947-1)
|
Stripping length (main cable) |
8 mm
|
Connection |
Connection to C rail
|
Connection type |
Spring-loaded/screw terminal, Connection design in TOP direction
|
Number of slots |
1
|
Input current at AC - max |
0 A
|
Input voltage at AC 50 Hz - min |
0 V
|
Input voltage at AC 50 Hz - max |
0 V
|
Input voltage at DC - min |
0 V
|
Input voltage at DC - max |
0 V
|
Output current at AC, 50 Hz - max |
0 A
|
Output voltage at AC 50 Hz - max |
0 V
|
Output voltage at DC - min |
0 V
|
Output voltage at DC - max |
0 V
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Potential isolation |
Through optocoupler: yes
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|