Eaton Moeller® series EMR6 Current monitoring relay, Current measuring range: 3 - 30 mA, 10 - 100 mA, 0.1 - 1 A, Supply voltage: 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC
Product Name |
Eaton Moeller® series EMR6 Current monitoring relay
|
Catalog Number |
184780
|
EAN |
4015081788163
|
Product Length/Depth |
103.7 mm
|
Product Height |
85.6 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.153 kg
|
Certifications |
EAC
CSA-C22.2 No. 14 UL 508 RMRS CCC GL |
Catalog Notes |
Extension of the measurement range possible with current transformers
|
Current measurement - min |
0.01 A
|
Current measurement - max |
1 A
|
Electric connection type |
Screw connection
|
Functions |
Monitoring of single-phase DC and AC networks
DC-voltage under current Single-phase under current possible DC-voltage over current Single-phase over current possible |
Monitoring function |
Overcurrent
Undercurrent |
Voltage measurement - min |
24 V
|
Voltage measurement - max |
240 V
|
Degree of protection |
Enclosure: IP50
Terminals: IP20 |
Lifespan, mechanical |
30,000,000 Operations
|
Mounting position |
As required
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
EMR Measuring and monitoring relays
|
Product category |
EMR Measuring and monitoring relays
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Shock resistance |
Class 2
|
LED indicator |
Status indication of energized output relay: Yellow LED
Other states depending on fault (see IL): Measured value Status indication of Supply voltage: Green LED Status indication of measured value: Red LED Status indication of Supply voltage: Green, solid light |
Type |
Current monitoring relay
|
Voltage type |
AC/DC
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
60 °C
|
Ambient storage temperature - min |
40 °C
|
Ambient storage temperature - max |
85 °C
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
|
Air discharge |
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
|
Burst impulse |
According to IEC/EN 61000-4-4, level 3
|
Electromagnetic compatibility |
According to IEC/EN 60947-6-2
|
Immunity to line-conducted interference |
Level 3 (according to IEC/EN 61000-4-6)
|
Immunity to radiation |
Level 3 (according to IEC/EN 61000-4-3)
|
Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
Connection type |
Snap fixing, top-hat rail IEC/EN 60715
|
Terminal capacity (flexible with ferrule) |
2 x 0.5-1.5 mm²
|
Terminal capacity (flexible with ferrule AWG) |
2 x 18-16
|
Terminal capacity (solid) |
1 x 0.5-2.5 mm²
|
Terminal capacity (solid AWG) |
18 - 14
|
Screwdriver size |
4 x 0.8 mm, Terminal screw
|
Tightening torque |
Min. 0.6 Nm, Screw terminals
0.8 Nm, Screw terminals |
Delay time |
Adjustable from 0.1 - 30 s, Response delay time
Switch-on delay: none = 0 or adjustable from 0.1 to 30 s |
On-delay |
0.1 - 30 ms
|
Timing cycle |
0.06 %/°C, Time error within temperature range
0.5 %, Time error within supply voltage 0.5 % Error within supply voltage (Measuring circuits) 30 s, Reset delay/Off-delay time |
Duty factor |
100 %, Power supply
|
Power consumption |
2.6 VA
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
240 V
|
Rated frequency - min |
50 Hz
|
Rated frequency - max |
60 Hz
|
Supply voltage |
24 - 240 V AC, 50/60 Hz
24 - 240 V DC |
Voltage tolerance |
0.85 x Uc
1.1 x Uc |
Hysteresis |
3 - 30 %
|
Input current |
Input B3-C: 0.1 - 1 A
Input B1-C: 0.003 - 0.03 A Input B2-C: 0.01 - 0.1 A |
Measuring cycle |
80 ms
|
Temperature error |
0.06 %/°C, Measuring circuits
|
Number of contacts (change-over contacts) |
2
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
0
|
Lifespan, electrical |
100,000 Operation (at 230 V, AC-12, 4 A)
|
Rated operational current (Ie) |
4 A at DC-12, 24 V
4 A at AC-12, 230 V |
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
3 A
|
Rated operational current (Ie) at DC-13, 24 V |
2 A
|
Rated operational voltage (Ue) at AC - max |
250 V
|
Short-circuit protection rating |
Max. 10 A Fast/gL, Fuse, Relay output contacts
|
Short-circuit protection rating |
Max. 10 A Fast/gL, Fuse, Relay output contacts
|