Eaton Moeller® series PKZ Trip indicator, 2 x 1 N/O, Push in terminals
Product Name |
Eaton Moeller® series PKZ Trip indicator
|
Catalog Number |
199329
|
Model Code |
AGM2-10-PKZ0-PI
|
EAN |
4015081974139
|
Product Length/Depth |
73 mm
|
Product Height |
92 mm
|
Product Width |
24 mm
|
Product Weight |
0.044 kg
|
Compliances |
RoHS conform
CE Marked |
Certifications |
CSA File No.: 165628
CSA Class No.: 3211-05 UL File No.: E36332 UL Category Control No.: NLRV UL 508 CE marking CSA-C22.2 No. 14 IEC 60947-4-1 UL CSA |
Electric connection type |
Spring clamp connection
|
Features |
Interlocked opposing contacts
|
Indication |
Short-circuits indicated locally by means of a red indicator that can be manually reset
|
Lifespan, electrical |
50,000 Operations
|
Lifespan, mechanical |
10,000 Operations
|
Model |
Top mounting
|
Mounting method |
Side mounting
|
Overvoltage category |
III
|
Pollution degree |
3
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Used with |
Motor protective circuit-breaker
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Terminal capacity (flexible with unisolated ferrule) |
1 x (0.5 - 2.5) mm²
2 x (0.5 - 2.5) mm² |
Terminal capacity (flexible with ferrule) |
1 x (0.5 - 1.5) mm²
2 x (0.5 - 1.5) mm² |
Terminal capacity (flexible) |
1 x (0.5 - 2.5) mm²
2 x (0.5 - 2.5) mm² |
Terminal capacity (solid) |
1 x (0.5 - 2.5) mm²
2 x (0.5 - 2.5) mm² |
Terminal capacity (solid/stranded AWG) |
20 - 14
|
Rated operational current (Ie) |
1 A at AC-15, 440 V 500 V
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
3.5 A
|
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V |
2 A
|
Rated operational current (Ie) at DC-13, 110 V |
0.5 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.25 A
|
Rated operational current (Ie) at DC-13, 60 V |
1 A
|
Rated operational voltage (Ue) at AC - max |
500 V
|
Rated operational voltage (Ue) at DC - max |
250 V
|
Safe isolation |
440 V, Between auxiliary contacts and main contacts, According to EN 61140
|
Safe isolation |
440 V, Between auxiliary contacts and main contacts, According to EN 61140
|
Switching capacity (auxiliary contacts, general use) |
5 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) |
A600, AC operated (UL/CSA)
Q300, DC operated (UL/CSA) |
Connection type |
Push in terminals
|
Control circuit reliability |
< 2 λ, < 1 failure at 100,000,000 Operations (at Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
2
|