Download document () of 20

EP-400139
Model code: XP-504-21-TERMINAL

Eaton Terminal, Capacitive multitouch (PCT), 21.5", 0 x Ethernet, 0 x USB3.0, 0 x RS-232

General specifications

Product Name
Eaton XP Panel PC
Catalog Number
EP-400139
Model Code
XP-504-21-TERMINAL
EAN
7640130099951
Product Length/Depth
544 mm
Product Height
335.5 mm
Product Width
75 mm
Product Weight
5.9 kg
Certifications
CE
UKCA
UL
UL File No.: E205091
Certified by UL for use in Canada
UL report applies to both US and Canada
UL 61010-1
RoHS

Features & Fuctions

Enclosure material
Aluminum (die-cast)
Features
Customer individual configuration
Fitted with:
Touch screen

General

Degree of protection
NEMA 12
IP65
Degree of protection (front side)
IP65
Explosion safety category for dust
ATEX dust-ex-protection, II 3D Ex tc IIIC T70°C U
Mounting method
Front build in possible
Product category
Panel PC
Type
Industrial PC
Voltage type
DC

Climatic environmental conditions

Ambient operating temperature - min
0 °C
Ambient operating temperature - max
45 °C
Ambient storage temperature - min
-20 °C
Ambient storage temperature - max
60 °C
Environmental conditions
Condensation: Non-condensing
Operating temperature - min
0 °C
Operating temperature - max
45 °C

Electrical rating

Rated operational voltage
24 V DC (power-supply - safety extra low voltage)
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
20 VDC
Supply voltage at DC - max
28 VDC

Display

Display lighting
LED
Dimmable via software
Display size
476.64 x 268.11 mm
16:9
Display type
TFT
Display viewing angle
89°/89°/89°/89° (left/right/up/down)
Lifespan
50,000 h (Service life of back-lighting)
Luminance intensity
350 cd/m²
Pixel resolution
1920 x 1080
WUXGA
Screen size (diagonal)
21.5 in
Touch technology
Capacitive multitouch (PCT)
Multi-touch touch panel touch sensor

Design verification

Equipment heat dissipation, current-dependent Pvid
16.8 W
Static heat dissipation, non-current-dependent Pvs
16.8 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Is the panel builder's responsibility.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.