Eaton Moeller® series LSR Hinge-operated safety switch, LSR, Safety hinge switch, Complete unit, 1 N/O, 1 NC, Insulated material, Screw terminal, -25 - +70 °C
Product Name |
Eaton Moeller® series LSR Hinge-operated safety switch
|
Catalog Number |
106851
|
EAN |
4015081066117
|
Product Length/Depth |
33 mm
|
Product Height |
91.5 mm
|
Product Width |
31 mm
|
Product Weight |
0.087 kg
|
Certifications |
CE
IEC/EN 60947 UL Category Control No.: NKCR CSA CSA-C22.2 No. 14 UL UL File No.: E29184 CSA File No.: 012528 IEC/EN 60947-5 UL 508 CSA Class No.: 3211-03 |
Catalog Notes |
Contacts with safety function, by positive opening to IEC/EN 60947-5-1
|
Type |
|
Features |
Forced opening
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Cable entry metrical
|
Enclosure material finishing |
Other
|
Operating frequency |
1800 Operations/h
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Enclosure material |
Plastic
|
Enclosure type |
Cuboid
|
Rated operational current (Ie) at DC-13, 110 V |
0.8 A
|
Rated operational current (Ie) at DC-13, 125 V |
1 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.5 A
|
Rated operational current (Ie) at DC-13, 24 V |
3 A
|
Rated operational current for specified heat dissipation (In) |
6 A
|
Sensor height |
91 mm
|
Sensor length |
32 mm
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Width sensor |
30 mm
|
Product category |
Safety hinge switch
|
Action |
2021118113756-Mechanical Limit Switches.xlsm-Data
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Actuator type |
Hollow shaft
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.13 W
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Number of safety auxiliary contacts |
0
|
Rated insulation voltage (Ui) |
500 V
|
Rated operational current (Ie) at AC-15, 125 V |
0 A
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
6 A
|
Rated operational current (Ie) at AC-15, 24 V |
10 A
|
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V |
4 A
|
Mounting position |
As required
|
Rated conditional short-circuit current (Iq) |
1 kA
|
Connection type |
Screw terminal
|
Degree of protection |
NEMA 4X (indoor use only)
NEMA 3R NEMA 12 IP65 NEMA 13 |
Interface type |
None
|
Lifespan |
1,000,000 mechanical Operations
|
Repetition accuracy |
0.02 mm (Contacts/switching capacity)
|
Shock resistance |
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
|
Supply frequency |
Max. 400 Hz, Contacts
|
Suitable for |
Safety functions
|
Short-circuit protection rating |
Max. 6 A gG/gL, Fuse, Contacts
|
Terminal capacity (flexible with ferrule) |
2 x (0.5 - 1.5) mm²
1 x (0.5 - 1.5) mm² |
Terminal capacity (solid) |
2 x (0.75 - 1.5) mm²
1 x (0.75 - 2.5) mm² |
Switching contact type |
Slow-action switch
|