Eaton Moeller® series M22 LED element, red, base fixing, 12-30VAC/DC
Product Name |
Eaton Moeller® series M22 Accessory LED
|
Catalog Number |
216561
|
EAN |
4015082165611
|
Product Length/Depth |
38 mm
|
Product Height |
10 mm
|
Product Width |
37 mm
|
Product Weight |
0.011 kg
|
Compliances |
CE Marked
|
Certifications |
EN 60947-5
UL 508 CSA Std. C22.2 No. 14-05 CSA Std. C22.2 No. 94-91 IEC 60947-5 VDE CSA-C22.2 No. 14-05 CSA-C22.2 No. 94-91 CSA File No.: 012528 CSA CSA Class No.: 3211-03 IEC/EN 60947-5 UL CE IEC 60947-5-1 UL File No.: E29184 UL Category Control No.: NKCR |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Light source
Diode |
Pollution degree |
3
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Connection to SmartWire-DT |
No
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
40 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Force for positive opening - min |
0 N
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Operating torque |
0.8 Nm
|
Rated insulation voltage (Ui) |
500 V
|
Rated operational current (Ie) - max |
14 mA
|
Rated operational current (Ie) - min |
5 mA
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Rated operational voltage (Ue) at AC - max |
30 V
|
Rated operational voltage (Ue) at AC - min |
12 V
|
Rated operational voltage (Ue) at DC - max |
30 V
|
Rated operational voltage (Ue) at DC - min |
12 V
|
Static heat dissipation, non-current-dependent Pvs |
0.45 W
|
Voltage type |
AC/DC
|
Fastening type |
Floor fastening
|
Mounting position |
As required
|
Light color |
Red
|
Connection type |
Base fixing
|
Lamp type |
LED
|
Overvoltage category |
III
|
Connection type (auxiliary circuit) |
Screw connection
|
Degree of protection |
IP20
|
Lamp holder |
None
|
Power consumption |
Max. 0.26 W
|
Lifespan, electrical |
100,000 h (at 25°C, according to EN60064)
|
Terminal capacity (stranded) |
0.5 - 2.5 mm²
|
Shock resistance |
Mechanical, According to IEC/EN 60068-2-27
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms |
Terminal capacity (solid) |
0.75 - 2.5 mm²
|