Eaton S711 Soft starter, 250 A, 200 - 575 V AC, Us= 110-240 V AC, with control unit, Frame size 3, IP00
Product Name |
Eaton S711 soft starter
|
Catalog Number |
EP-401527
|
EAN |
4015082970994
|
Product Length/Depth |
385 mm
|
Product Height |
218 mm
|
Product Width |
202 mm
|
Product Weight |
11.8 kg
|
Certifications |
CE
|
Type |
Soft starter for three-phase loads, with control unit and pump algorithm, DC Brake, Soft Brake, Jog, Bluetooth
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Display
Motor overload protection Internal bypass |
Pollution degree |
3
|
Class |
Adjustable
|
Climatic proofing |
5 to 95% Relative Humidity
|
Connection to SmartWire-DT |
No
|
Rated impulse withstand voltage (Uimp) |
6000 V
|
Frame size |
FS3
|
Altitude |
Max 4000 m (Above 1000 m for detailed derating use S711 Select Software)
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Assigned motor power at 200/208 V, 60 Hz, 3-phase |
75 HP
|
Assigned motor power at 220/230 V, 60 Hz, 3-phase |
100 HP
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
200 HP
|
Assigned motor power in-delta at 220/230 V, 60 Hz |
125 HP
|
Assigned motor power in-delta at 460/480 V, 60 Hz |
250 HP
|
Assigned motor power in-delta at 575/600 V, 60 Hz |
350 HP
|
Equipment heat dissipation, current-dependent Pvid |
1125 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Mains voltage - max |
632.5 V
|
Mains voltage - min |
170 V
|
Output voltage |
250 V AC (relay outputs)
|
Number of outputs |
3 Relay Outputs (1 fixed, 2 programmable)
|
Voltage type |
AC
|
Rated operational voltage (Ue) - min |
200 V
|
Rated operational voltage (Ue) at AC - max |
575 V
|
Rated power three-phase motor, inline, at 230 V |
75 kW
|
Rated power three-phase motor, inline, at 400 V |
90 kW
|
Rated power three-phase motor, inside delta, at 230 V |
110 kW
|
Rated power three-phase motor, inside delta, at 400 V |
185 kW
|
Static heat dissipation, non-current-dependent Pvs |
120 W
|
Voltage rating - max |
575 V
|
Application |
|
Protection |
Optional terminal cover for Finger and back-of-hand proof, Protection against direct contact
|
Mounting position |
As required
|
Drop-out voltage |
0 - 90 V, AC operated
|
Degree of protection |
IP00
NEMA Other |
Functions |
Single direction
Torque control DC-Brake Soft-Brake Forward & reverse jog |
Overload cycle |
AC-53b: 3.5-20:580
|
Pick-up voltage |
93.5 - 264.0 V AC
|
Radio interference class |
Class A (IEC 60947-4-2)
|
Fault memory |
1000 Faults
|
Interfaces |
Modbus RTU (built-in)
Bluetooth (built-in) |
Kickstart |
600% (Kickstart current)
Max. 2000 ms (Kickstart Duration) |
Rated control voltage (Uc) |
110 - 240 V AC (-15%/+10%)
|
Supply frequency |
50/60 Hz, fLN, Main circuit
|
Terminal capacity (stranded) |
1 x (95 - 240) mm², Main cables
1x (1 - 2.5) mm², Control circuit cables |
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
110 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
110 V
|
Rated insulation voltage (Ui) |
600 V
|
Rated operational current (Ie) at AC-11 |
3 A
|
Rated operational current (Ie) at AC-53 |
250 A
|
Rated operational current (Ie) at AC-53, in-delta |
375 A
|
Rated operational current for specified heat dissipation (In) |
250 A
|
Rated operational power at 220/230 V, 50 Hz |
75 kW
|
Rated operational power at 400 V, 50 Hz |
90 kW
|
Rated operational power at 500 V, 50 Hz |
185 kW
|
Rated operational power in-delta at 220/230 V, 50 Hz |
110 kW
|
Rated operational power in-delta at 400 V, 50 Hz |
185 kW
|
Rated operational power in-delta at 500 V, 50 Hz |
250 kW
|
Rated operational voltage (Ue) - max |
575 V
|
Ramp/run-up time |
180 s
|
Shock resistance |
15 g, Mechanical
|
Tightening torque |
0.5 Nm, Screw terminals, Control circuit cables
40 Nm, Main cables |
Start voltage |
Max. 600% FLA, Min. 100% FLA, Soft start function
|
Startup class |
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 10 (star-delta replacement) CLASS 30 (6 x Iₑ for 30 s) |
Terminal capacity (flexible with ferrule) |
1 x (95 - 240) mm², Main cables
1x (1 - 2.5) mm², Control circuit cables |
Terminal capacity (solid) |
1 x (95 - 240) mm², Main cables
1x (1 - 2.5) mm², Control circuit cables |
Terminal capacity (solid/stranded AWG) |
1 x (3/0 - 500), Main cables
1x (28 - 12) , Control circuit cables |