Eaton Moeller® series RMQ16 Illuminated pushbutton actuator, green, momentary, +filament lamp 24V Q25LT-GN/WB
Product Name |
Eaton Moeller® series RMQ16 Illuminated pushbutton actuator
|
Catalog Number |
089190
|
EAN |
4015080891901
|
Product Length/Depth |
59 mm
|
Product Height |
25 mm
|
Product Width |
25 mm
|
Product Weight |
0.011 kg
|
Certifications |
CSA
UL Category Control No.: NKCR CSA-C22.2 No. 14-05 UL 508 IEC/EN 60947 UL CE CSA Class No.: 3211-03 CSA File No.: 46552 UL File No.: E29184 IEC/EN 60947-5 |
Bezel color |
Black
|
Bezel material |
Plastic
|
Design |
Flat
|
Fitted with: |
Filament bulb (24 V)
|
Inscription |
Blank
|
Degree of protection |
NEMA 1
IP65 |
Degree of protection (front side) |
NEMA 1
IP65 |
Lifespan, mechanical |
3,000,000 Operations
|
Opening diameter |
16 mm
|
Operating frequency |
3600 Operations/h
|
Overvoltage category |
III
|
Pollution degree |
3
|
Product category |
RMQ16
|
Rated impulse withstand voltage (Uimp) |
800 V AC
|
Size |
Front dimensions: 25 x 25 mm
|
Suitable for |
Illumination
|
Terminal size |
2.8 x 0.8 mm to DIN 46244, Blade terminal
2.8 x 0.8 mm to DIN 46247 and IEC 60760, Fast-on connectors |
Type |
Illuminated pushbutton actuator
|
Mounting position |
As required
|
Shock resistance |
40 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27 |
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature (enclosed) - min |
25 °C
|
Ambient operating temperature (enclosed) - max |
40 °C
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Rated insulation voltage (Ui) |
250 V
|
Rated operational voltage (Ue) at AC - max |
24 V
|
Actuating force |
4 N
|
Actuator color |
Green
|
Actuator function |
Spring-return
Momentary |
Connection to SmartWire-DT |
No
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
1 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|