Eaton EU5C Gateway, SmartWire-DT, 99 SWD modules at CANopen
Product Name |
Eaton EU5C Communication module
|
Catalog Number |
116307
|
EAN |
4015081160471
|
Product Length/Depth |
127 mm
|
Product Height |
90 mm
|
Product Width |
35 mm
|
Product Weight |
0.159 kg
|
Certifications |
UL
EN 50178 IEC/EN 61131-2 CSA File No.: 2324643 UL File No.: E29184 UL Category Control No.: NKCR CSA CSA Class No.: 3211-07 |
Features |
Potential isolation (Fieldbus Interface)
Overload proof |
Functions |
For connection to CANopen® field bus
|
Operating mode |
Address allocation via DIP switch
|
Degree of protection |
IP20
|
Mounting method |
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories) Wall mounting/direct mounting Top-hat rail fixing (according to IEC/EN 60715, 35 mm) |
Overvoltage category |
II
|
Pollution degree |
2
|
Product category |
SmartWire-DT coordinators
|
Repetition rate |
1 s
|
Residual ripple |
≤ 5 % (input voltage)
|
Suitable for |
Safety functions
|
Terminal capacity |
0.25 - 1.5 mm², flexible with ferrule
0.2 - 1.5 mm², solid 24 - 16 AWG, solid or stranded |
Voltage type |
DC
|
Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
Mounting position |
As required
|
Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
Air pressure |
795 - 1080 hPa (operation)
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature - max |
55 °C
|
Ambient storage temperature - min |
-40 °C
|
Ambient storage temperature - max |
70 °C
|
Climatic proofing |
In accordance with IEC 60068-2
|
Operating temperature - min |
-25 °C
|
Operating temperature - max |
55 °C
|
Relative humidity |
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
Burst impulse |
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3 1 kV |
Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
Electromagnetic fields |
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008) 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) |
Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
Radio interference class |
Class A (EN 55011)
|
Surge rating |
0.5 kV, Supply cable, Surge (IEC/EN 61131-2:2008, Level 1), EMC
|
Voltage dips |
≤ 10 ms, Bridging voltage dips
|
Inrush current |
12.5 A (for 6 ms)
|
Power loss |
Normally 1 W
|
Rated control supply voltage |
24 V DC (UAUX, -15 %/+20 %)
24 V DC (UPOW, -15 %/+20 %) |
Rated operational current (Ie) |
0.6 A
|
Rated operational voltage |
Typically UAUX -0.2 V (for 24 V DC slaves)
14.5 V (± 3 % - SmartWire-DT) |
Short-circuit protection |
Yes, Short-circuit rating, SmartWire-DT supply voltage
No, external fuse FAZ Z3, Supply voltage UAux |
Supply current - max |
0.7 mA
|
Supply voltage at AC, 50 Hz - min |
0 V
|
Supply voltage at AC, 50 Hz - max |
0 V
|
Supply voltage at DC - min |
20.4 V
|
Supply voltage at DC - max |
28.8 V
|
Addressing |
Address set automatically
Address range: 1 - 32 |
Connection |
SmartWire-DT blade terminal SWD4-8MF2
The connection to CANopen® is carried out via the 9 pole SUB-D plug as slave. Used to connect the SmartWire-DT communication system to industrial field bus systems. Powers SmartWire-DT modules and switchgear SmartWire-DT gateway for connecting up to 99 SmartWire-DT modules to the field bus and for powering the SmartWire-DT modules and switchgear. |
Connection type |
1 x SUB-D plug, 9-pole, Field bus interface
Push in terminals, Supply voltage SWD: Plug, 8-pole |
Data transfer rate |
125 kBit/s, SmartWire-DT
250 kBit/s, SmartWire-DT Up to 1 MBit/s, Fieldbus interface 128 Byte, Fieldbus interface, Output data, max. 128 Byte, Fieldbus interface, Input data, max. Automatic baud rate detection for rates ranging from 10 kBit/s to 1 Mbit/s. |
Interfaces |
Module type: CANopen® slave
Status display fieldbus interface for CAN with Multi color LED Terminating resistor switchable via DIP switches |
LED indicator |
Status indication of SmartWire-DT network: Configurable green or red LED
Status indication of SmartWire-DT master: Green and red LEDs Status indication of Supply voltage: LED |
Number of modules |
99 (SmartWire-DT)
|
Protocol |
CANopen®
|
Station |
2 - 32, Station address, Fieldbus interface
SmartWire-DT master, SmartWire-DT network |
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Potential isolation |
Between UPow and 15 V SmartWire-DT supply voltage: no
Supply voltage UAUX: no |
Protection against polarity reversal |
Yes
Yes, for supply voltage (Siemens MPI optional) |
Equipment heat dissipation, current-dependent Pvid |
3.8 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
1 W
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|