Photo is representative
Download
Eaton Moeller® series E59 Proximity Sensor, M30, analog, Sn=1-25mm, 15-30VDC, 4-20mA, line 2m
Product Name |
Eaton E59 AccuProx analog inductive proximity sensor
|
Catalog Number |
166686
|
EAN |
4015081643509
|
Product Length/Depth |
152.4 mm
|
Product Height |
44.45 mm
|
Product Width |
127 mm
|
Product Weight |
0.45 kg
|
Certifications |
CSA Class No.: 3211-03
IEC/EN 60947-5-2 UL CE CSA-C22.2 No. 14 UL Category Control No.: NRKH, NRKH7 CSA UL 508 UL File No.: E166051 CSA File No.: 50513 |
Model Code |
E59-A30C125C02-C1
|
Type |
Inductive sensor
|
Electric connection type |
Cable
|
Enclosure material finishing |
Other
|
Actuation type |
Metallic Target
|
Enclosure material |
Metal
|
Enclosure type |
Cylinder, screw-thread
|
Category (EN 954-1) |
B
|
Explosion safety category for dust |
None
|
Explosion safety category for gas |
None
|
Safety performance level (EN ISO 13849-1) |
None
|
SIL (IEC 61508) |
None
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-40 °C
|
Diameter sensor |
30 mm
|
Number of contact energized outputs with signalling function |
0
|
Number of outputs (protected contact energized) |
0
|
Number of outputs (protected semiconductor) |
0
|
Number of outputs (semiconductor with signaling function) |
0
|
Output current at protected output - max |
20 mA
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Output current |
4 - 20 mA
|
Voltage type |
DC
|
Mounting method |
Non-flush mounting
|
Material |
Stainless steel
|
Connection type |
3-wire/4-wire
2 m connection cable |
Installation type |
Not flat
|
Degree of protection |
IP67
NEMA 4X, 6, 13 |
Interface type |
None
|
LED indicator |
Status indication of Operating voltage: Green LED
Status indication of Switching state: Red LED |
Switch function type |
Other
|
Shock resistance |
30 g, Mechanical, Shock duration 11 ms
|
Switching frequency |
100 Hz
|
Voltage rating - max |
30 V
|
Width sensor |
0 mm
|
Product category |
E59 AccuProx Series
|
Switching output type |
Analog
|
Temperature drift of sn |
10 %
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
30 V
|
Rated control supply voltage (Us) at DC - min |
15 V
|
Rated switching distance (Sn) - max |
25 mm
|
Rated switching distance (Sn) - min |
1 mm
|
Repeatability |
1 %
|
Sensor height |
0 mm
|
Sensor length |
69.6 mm
|
Supply voltage - max |
30 V
|
Supply voltage - min |
15 V
|