Reset
NZMN2-MX90-BT-NA. NZM2 PXR20 circuit breaker, 90A, 3p, box terminal, UL/CSA
Product Name |
Eaton Moeller series NZM molded case circuit breaker electronic
|
Catalog Number |
192440
|
EAN |
4015081931682
|
Product Length/Depth |
149 mm
|
Product Height |
195 mm
|
Product Width |
105 mm
|
Product Weight |
3.238 kg
|
Compliances |
RoHS conform
|
Certifications |
CSA-C22.2 No. 5-09
UL (Category Control Number DIVQ) Specially designed for North America CE marking UL 489 UL508 CSA (File No. 22086) UL listed UL/CSA CSA certified IEC UL (File No. E31593) IEC 60947-2 CSA (Class No. 1432-01) |
Model Code |
NZMN2-MX90-BT-NA
|
Amperage Rating |
90 A
|
Voltage rating |
690 V - 690 V
|
Circuit breaker frame type |
NZM2
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Thermal protection
|
Mounting Method |
Fixed
Built-in device fixed built-in technique |
Equipment heat dissipation, current-dependent |
6.68 W
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
40 °C
|
Rated insulation voltage (Ui) |
690 V
|
Rated operating power at AC-3, 230 V |
22 kW
|
Rated operating power at AC-3, 400 V |
45 kW
|
Switch off technique |
Electronic
|
Degree of protection |
IP20
|
Direction of incoming supply |
As required
|
Electrical connection type of main circuit |
Other
|
Number of poles |
Three-pole
|
Functions |
Phase failure sensitive
Current limiting circuit breaker Motor protection |
Type |
Circuit breaker
|
Special features |
|
Application |
Branch circuits, feeder circuits
|
Rated operational current for specified heat dissipation (In) |
90 A
|
Short-circuit release non-delayed setting - max |
1260 A
|
Short-circuit release non-delayed setting - min |
180 A
|
Handle type |
Rocker lever
|
Instantaneous current setting (Ii) - max |
1260 A
|
Instantaneous current setting (Ii) - min |
180 A
|
Overload current setting (Ir) - max |
90 A
|
Overload current setting (Ir) - min |
36 A
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz |
50 kA
|
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz |
50 kA
|
Rated operating voltage Ue (UL) - max |
480 V
|
Release system |
Electronic release
|
Rated short-circuit breaking capacity Icu (IEC/EN 60947) at 400/415 V, 50/60 Hz |
50 kA
|