Eaton XV-102 Touch panel, 24 V DC, 3.5z, TFTcolor, ethernet, SWDT, PLC
Product Name |
Eaton XV-102 Touch panel
|
Catalog Number |
153524
|
EAN |
7640130097599
|
Product Length/Depth |
136 mm
|
Product Height |
30 mm
|
Product Width |
100 mm
|
Product Weight |
0.275 kg
|
Certifications |
DNV GL
EN 50178 CSA File No.: UL report applies to both US and Canada IEC/EN 61131-2, CE UL UL508 IEC/EN 61000-6-4 EN 60950 UL Category Control No.: NRAQ UL File No.: E205091 CUL508 cULus IEC/EN 61131-2 UL 60950 CSA Class No.: none Certified by UL for use in Canada IEC/EN 61000-6-2 EAC |
Model Code |
XV-102-BE-35TQRC-10
|
Type |
Coordinator for the SmartWire-DT communications system
|
Features |
Fanless CPU and system cooling, natural convection-based passive cooling
UL508, cUL approvals Target and web visualization Ethernet interface USB device Overload proof Portrait format Slot for SD card |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Numeric keyboard
1 x USB device (built-in interface) Message indication 1 x Ethernet 10/100 Mbps (built-in interfaces) Alpha numeric keyboard Color display 1 x SmartWire-DT (built-in interface) Message system (incl. buffer and confirmation) Recipes Printer output SW interfaces |
Fuse type |
Built-in fuse (not accessible)
|
Addressing |
Address set automatically
|
Connection to SmartWire-DT |
Yes
|
Enclosure material |
Plastic
|
Supply voltage at AC, 50 Hz - max |
0 VAC
|
Supply voltage at AC, 50 Hz - min |
0 VAC
|
Supply voltage at AC, 60 Hz - max |
0 VAC
|
Supply voltage at AC, 60 Hz - min |
0 VAC
|
Supply voltage at DC - max |
28.8 VDC
|
Supply voltage at DC - min |
20.4 VDC
|
Width of the front |
136 mm
|
Product category |
SmartWire-DT coordinators
|
Resolution |
|
Air pressure |
795 - 1080 hPa (operation)
|
Explosion safety category for dust |
ATEX dust-ex-protection, II 3D Ex II T70°C IP5x: Zone 22, Category 3D
ATEX dust-ex-protection, in relation to CE |
Display size |
70 x 53 mm
|
Backup time |
10 years, typ. (time at zero voltage)
|
Explosion safety category for gas |
Explosion protection according to EN 61241-1
Explosion protection according to EN 60079-0 Explosion protection according to EN 13463_x |
Memory capacity |
64,000 kByte
|
Ambient operating temperature - max |
50 °C
|
Ambient operating temperature - min |
0 °C
|
Ambient storage temperature - max |
60 °C
|
Ambient storage temperature - min |
-20 °C
|
Built-in depth |
25 mm
|
Equipment heat dissipation, current-dependent Pvid |
5 W
|
Front height |
100 mm
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Number of buttons (programmable function) |
0
|
Number of buttons with LED |
0
|
Number of grey-scales/blue-scales of display |
0
|
Number of HW-interfaces (industrial ethernet) |
1
|
Number of HW-interfaces (other) |
1
|
Battery runtime |
Back-up of real-time clock: CR 2032 (190 mA/h), zero maintenance (soldered)
|
Voltage type |
DC
|
Connection |
SmartWire-DT blade terminal SWD4-8MF2
|
Operating system |
Windows CE 5.0 (license included)
|
Communication interface |
SmartWire-DT master
|
Software |
XSOFT-CODESYS-3, PLC-Programming software, Engineering
EPAM, Visualization software, Engineering GALILEO, Visualization software, Engineering XSOFT-CODESYS-2, PLC-Programming software, Engineering XSOFT-CODESYS-3, Visualization software, Engineering XSOFT-CODESYS-2, Visualization software, Engineering |
Mounting method |
Flush mounting - Clearance: Width x Height x Depth ≥ 30 mm (1.18")
Flush mounting - Inclination from vertical: ±45° (if using natural convection) Flush mounting |
Display contrast ratio |
300:1
|
Number of slots |
1 (for SD-Card)
|
Display lighting |
LED
Dimmable via software |
Display type |
Color display, TFT
TFT Standard front with standard membrane (fully enclosed) |
Protection against polarity reversal |
Yes
Yes, for supply voltage (Siemens MPI optional) |
Relative humidity |
10 - 95 % (non-condensing)
|
Lifespan |
40,000 h (Service life of back-lighting)
|
Residual ripple |
≤ 5 % (input voltage)
|
Connection type |
Push in terminals, Supply voltage
SWD: Plug, 8-pole |
Rated control supply voltage |
24 V DC (UAUX, -20 %/+25 %)
24 V DC (UPOW, -20 %/+25 %) |
Inrush current |
12.5 A (for 6 ms)
|
Data transfer rate |
125 kBit/s, SmartWire-DT
250 kBit/s, SmartWire-DT |
Degree of protection |
IP20
IP20, rear |
Luminance intensity |
250 cd/m²
|
Degree of protection (front side) |
IP65
NEMA 4X |
Number of colors of the display |
65536
|
Station |
SmartWire-DT master, SmartWire-DT network
|
Vibration resistance |
According to IEC/EN 60068-2-6
|
Processor |
RISC CPU, 32 Bit, 400 MHz
|
RoHs conformity |
Yes
|
Supply current |
3 A, Imax, Supply voltage UAux
If SmartWire-DT modules with a total power consumption > 0.7 A are connected, a power feeder module EU5C-SWD-PF2 has to be used; SmartWire-DT supply 0.7 A, Imax, SmartWire-DT supply |
Memory |
32 kByte internal NVRAM (retained data)
SD Memory Card Slot: SDA Specification 1.00 (External) 128 MByte internal NAND-Flash (can be used for data backup) 64 MByte internal DRAM (OS, Program and data memory) |
Functions |
Process default value (input) possible
Additional software components, loadable Process value representation (output) possible SmartWire-DT coordination |
Touch technology |
Touch sensor (glass with foil), Resistive touch protective screen
Resistive touch Glass with film touch sensor |
Model |
Insulating enclosure and front plate
|
Interfaces |
Ethernet (100Base-TX/10Base-T)
USB 2.0 device (not galvanically isolated) |
LED indicator |
Status indication of SmartWire-DT network: Configurable green or red LED
Status indication of SmartWire-DT master: Green and red LEDs Status indication of Supply voltage: LED |
Voltage dips |
5 ms from undervoltage (19.2 V DC)
≤ 10 ms, Bridging voltage dips ≤ 10 ms from rated voltage (24 V DC) |
Number of HW-interfaces (parallel) |
0
|
Number of HW-interfaces (RS-232) |
0
|
Number of HW-interfaces (RS-422) |
0
|
Number of HW-interfaces (RS-485) |
0
|
Number of HW-interfaces (serial TTY) |
0
|
Number of HW-interfaces (USB) |
1
|
Number of HW-interfaces (wireless) |
0
|
Number of interfaces (PROFINET) |
0
|
Number of online/runtime languages |
100
|
Number of password levels |
200
|
Number of pixels (horizontal) |
320
|
Number of pixels (vertical) |
240
|
Number of SmartWire-DT slaves |
99
|
Number of system buttons |
1
|
Operating temperature - max |
50 °C
|
Operating temperature - min |
0 °C
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Repetition rate |
1 s
|
Screen size (diagonal) |
3.5 in
|
Static heat dissipation, non-current-dependent Pvs |
5 W
|
Permissible voltage |
18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %)
18.0 - 31.2 V DC, absolute with ripple 35 V DC (for a duration of < 100 ms) 19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %) |
Potential isolation |
Supply voltage UAUX: no
Between UPow and 15 V SmartWire-DT supply voltage: no Power supply: no |
Power consumption |
2.5 W (USB Slave to USB Host)
9.5 W total Max. 5 W 5 W |
Protocol |
Other bus systems
MODBUS EtherNet/IP TCP/IP |
Rated operational current (Ie) |
0.7 A
|
Rated operational voltage |
14.5 V (± 3 % - SmartWire-DT)
Typically UAUX -0.2 V (for 24 V DC slaves) 24 V DC (power-supply - safety extra low voltage) |
Short-circuit protection |
No, external fuse FAZ Z3, Supply voltage UAux
Yes, Short-circuit rating, SmartWire-DT supply voltage |
Shock resistance |
Mechanical, According to IEC/EN 60068-2-27
|
Terminal capacity |
0.25 - 1.5 mm², flexible with ferrule
0.2 - 1.5 mm², solid 24 - 16 AWG, solid or stranded |