Kunnskapssøk
Last ned dokumentet () av 20

141908
FAZT-B40/1

Eaton Moeller series xEffect - FAZ-T MCB. FAZ-T, 1-pole, tripping characteristic: B, rated current In: 40 A

Generelle spesifikasjoner

Product Name
Eaton Moeller series xEffect - FAZ-T MCB
Catalog Number
141908
EL Number
1605516
EAN
4015081386383
Product Length/Depth
80 mm
Product Height
75.5 mm
Product Width
17.7 mm
Product Weight
0.12 kg
Compliances
RoHS compliant
Certifications
IEC/EN 60947-2
EN45545-2
IEC 61373
Model Code
FAZT-B40/1

Additional information

Current limiting class
3
Features
Can be fitted with auxiliary accessories
Suitable for IT systems
Suitable for Rolling Stock applications
Functional group
Overcurrent protection
Functions
Overload protection
Short Circuit protection
Internal resistance at room temperature (single-pole, 50 Hz)
2.6 mΩ
Used with
FAZ-T
Miniature circuit breaker

Delivery program

Amperage Rating
40 A
Application
  • Industrial and commercial applications
  • Utilities and OEM control panels
  • Renewable energy installations
  • IT and data centre auxiliary circuits
  • Railway and transportation systems
  • A2L refrigerant environments, etc.
Nominal current
40 A
Number of poles
Single-pole
Number of poles (protected)
1
Number of poles (total)
1
Release characteristic
B
Tripping characteristic
B
Type
  • FAZ-T
  • Miniature circuit breaker

Design verification as per IEC/EN 61439

10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.

Design verification as per IEC/EN 61439 - technical data

Ambient operating temperature - max
75 °C
Ambient operating temperature - min
-40 °C
Rated operational current for specified heat dissipation (In)
40 A

Technical data - electrical

Direction of incoming supply
Bidirectional
Frequency rating
50 Hz / 60 Hz
Frequency rating - max
60 Hz
Frequency rating - min
50 Hz
Lifespan, electrical
>4000 operating cycles
Operational voltage (IEC/EN 60947-2) - max
254 VAC
Operational voltage at DC (EC/EN 60947-2) - max
60 VDC
Overvoltage category
III
Pollution degree
2
Rated impulse withstand voltage (Uimp)
4 kV
Rated insulation voltage (Ui)
440 V
Rated operational voltage (Ue) - max
240 V
Rated service short-circuit breaking capacity (IEC/EN 60898-1) - Ics
7.5 kA
Rated service short-circuit breaking capacity (IEC/EN 60947-2) - Ics
10 kA
Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V
10 kA
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V
20 kA
Rated switching capacity (IEC/EN 60898-1)
10 kA
Rated switching capacity (IEC/EN 60947-2)
20 kA
Rated switching capacity (IEC/EN 60947-2) at max voltage rating
15 kA
Selectivity class
3
Voltage rating
240 V AC
Voltage rating (IEC/EN 60898-1)
230 VAC
Voltage rating (IEC/EN 60947-2)
240 V AC
Voltage type
AC

Technical data - mechanical

Built-in depth
65.5 mm
Busbar material thickness
0.8 mm - 2 mm
Connectable conductor cross section (multi-wired) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (solid-core) - min
1 mm²
Contact position indicator color
Red = ON
Green = OFF
Degree of protection
IP20 (device)
IP40 (when installed in enclosure)
Frame
45 mm
Lifespan, mechanical
10000 operating cycles
Mounting Method
Two lock-in position on DIN rail (EN 50022)
Mounting position
As required
Mounting width
17.7 mm
Mounting width per pole
17.7 mm
Terminal capacity
1 mm² - 25 mm²
Terminal protection
Touch-safe (VBG 4, ÖVE EN-6)
Terminals (top and bottom)
Screw-type with pressure plate
Tightening torque
Max. 2.4 Nm
Width in number of modular spacings
1

Eksporter produktspesifikasjoner

Serial Number Verified :
Authenticated: ✓
The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product.

Autentiser produktet

Skriv inn ditt serienummer på 16-17 siffer
Serienummeret du oppgir kan ikke inneholde spesialtegn. Serienummeret du har oppgitt er feil, det må bestå av 16 eller 17 siffer. Finner ikke serienummeret du har oppgitt. Prøv på nytt eller rapporter dette problemet for å få hjelp. Serienummeret du har oppgitt samsvarer ikke med produktet. Kontroller produktets serienummer og prøv på nytt. Klikke her for å gå til produktsiden for serienummeret du har oppgitt Serienummeret er kjent for Eaton for å være mistenkelig, prøv på nytt eller rapporter dette problemet for å få hjelp.
Serienummer
Tilbakestill Serienummeret er kjent for Eaton for å være mistenkelig, prøv på nytt eller rapporter dette problemet for å få hjelp. Serienummeret gjenkjennes ikke av Eaton og er ugyldig. Bruk dette skjemaet for å rapporter dette problemet for å få hjelp.
Oppgi den sekssifrede autentiseringskoden
Produktet du har oppgitt er mistenkelig! Prøv på nytt eller rapporter dette problemet for å få hjelp. Autentiseringskoden du har oppgitt samsvarer ikke med våre registreringer for dette serienummeret. Prøv på nytt eller rapporter dette problemet for å få hjelp. Ugyldig autentiseringskode. Lengden må være seks tegn rapporter dette problemet for å få hjelp. Autentiseringskode kreves rapporter dette problemet for å få hjelp.
Fullfør Captcha-utfordringen før du autentiserer.
x
Rapporter et problem
Oppgi fullt navn.
x
Takk, problemet er registrert og produktteamet vårt kontakter deg snart.