Photo is representative
Download
Eaton EU6E SWD Block module I/O module IP69K, 24 V DC, 2 inputs with power supply, 2 outputs with separate power supply, 4 M12 I/O sockets
| Product Name |
Eaton EU6E I/O module
|
| Catalog Number |
183264
|
| Model Code |
EU6E-SWD-2D2D-1
|
| EAN |
4015081781973
|
| Product Length/Depth |
34 mm
|
| Product Height |
156.8 mm
|
| Product Width |
60.8 mm
|
| Product Weight |
0.25 kg
|
| Certifications |
CSA
UL IEC/EN 61131-2 |
| Catalog Notes |
with supply
|
| Electric connection type |
Screw connection
|
| Features |
Short-circuit protection (sensor supply)
Overload proof (with diagnostics) Overload protection (sensor supply) Fieldbus connection over separate bus coupler possible |
| Functions |
Short-circuit protection, outputs available
For connection of digital I/O signals |
| Current consumption |
50 mA, SmartWire-DT network, 24 V, without sensor and without I/O supply
70 mA, Max. current consumption per M12 I/O plug, Sensor supply, SmartWire-DT network |
| Degree of protection |
IP69K
|
| Mounting method |
Screw fixing (M4)
Wall mounting/direct mounting |
| Overvoltage category |
II
|
| Pollution degree |
3
|
| Product category |
SmartWire-DT slave
|
| Residual ripple |
≤ 5 % (input voltage)
|
| Type |
Digital modules
|
| Voltage type |
DC
|
| Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
| Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Mounting position |
As required
|
| Shock resistance |
30 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature - max |
55 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Ambient storage temperature - max |
70 °C
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2 |
| Environmental conditions |
Condensation: permissible
|
| Operating temperature - min |
-25 °C
|
| Operating temperature - max |
55 °C
|
| Relative humidity |
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
| Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
| Burst impulse |
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3 1 kV, Signal cable, according to IEC/EN 61131-2, Level 3 |
| Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
| Electromagnetic fields |
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008) 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008) |
| Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
| Radio interference class |
Class A (EN 55011)
|
| Surge rating |
0.5 kV, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC |
| Input current |
4 mA (at 24 V DC, Digital inputs)
|
| Input current at signal 1 |
4 mA
|
| Output current |
0.5 A
|
| Power loss |
1.6 W
|
| Rated operational voltage |
24 V DC (-15 %/+ 20 % - power supply)
|
| Short-circuit tripping current |
Max. 1.2 A over 3 ms, Digital semi-conductor outputs
|
| Supply voltage at AC, 50 Hz - min |
0 VAC
|
| Supply voltage at AC, 50 Hz - max |
0 VAC
|
| Supply voltage at DC - min |
20.4 VDC
|
| Supply voltage at DC - max |
28.8 VDC
|
| Connection to SmartWire-DT |
Yes
|
| Connection type |
SWD-IN : M12 plug (A-keyed), 5 pole
5-pin M12 socket (A-keyed), Supply and I/O sensor SWD-OUT: M12 socket (A-keyed), 5 pole |
| Data transfer rate |
Setting automatically
2 MBit/s, SmartWire-DT |
| LED indicator |
Status indication of SmartWire-DT network: Green LED
Status indication of input: Yellow LED |
| Protocol |
Other bus systems
|
| Station |
SmartWire-DT slave, SmartWire-DT network
|
| Input delay |
< 0.2 ms
|
| Lamp load |
≤ 3 W (at RLL)
|
| Limit value type 1 |
Low: < 5 V DC
High: > 15 V DC |
| Number of inputs (digital) |
2
|
| Number of outputs (digital) |
2
|
| Output |
2 Transistor Outputs
|
| Switching capacity |
IEC/EN 60947-5-1, utilization category DC-13, Digital outputs
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Protection against polarity reversal |
Yes
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
1.6 W
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|