Eaton Distribution parts. H.b.c fuse switch strip, rated operational current 160A, max. fuse-link 500V/160A, max. fuse-link 690V/160A, size 00, with safety monitoring
Product Name |
Eaton Distribution parts
|
Catalog Number |
106216
|
EAN |
4015081059867
|
Product Length/Depth |
610 mm
|
Product Height |
136 mm
|
Product Width |
49 mm
|
Product Weight |
1.25 kg
|
Compliances |
EN 60947-5-1
RoHS conform |
Certifications |
IEC/EN 60255
VDE 0435 Part 303 |
Model Code |
NH-SLS-00/160-60-SI
|
Used with |
20 mm x 5/10 mm rail
12 mm x 5/10 mm rail Double T profile Triple T profile 25 mm x 5/10 mm rail 15 mm x 5/10 mm rail 30 mm x 5/10 mm rail Busbar fuse material 60 mm system |
Number of poles |
Three-pole
|
Frame |
00
|
Frequency rating |
50 Hz - 60 Hz
|
Terminals |
Lift terminals
|
Voltage rating at AC |
|
Voltage range |
(0.8 - 1.1) x Ue
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Admissible back-up fuse - max |
4 A gL
|
Screw diameter for flange connection |
M8
|
Admissible heat dissipation (NH-SE) - max |
12 W
|
Ambient operating temperature - max |
40 °C
|
Ambient operating temperature - min |
-5 °C
|
Conventional thermal current Ith of auxiliary contacts (1-pole, open) |
4 A
|
Fuse current rating at 500 V - max |
160 A
|
Heat dissipation at Ith AC without NH-SE |
20 W
|
Operating altitude without derating - max |
2000 mm
|
Pick-up time - max |
500 ms
|
Rated insulation voltage (Ui) |
400 V
|
Rated operating voltage (Ue) at AC - max |
690 V
|
Rated operational current (gL/gG) - max |
160 A
|
Rated uninterrupted current (Iu) |
160 A
|
Rated impulse withstand voltage (Uimp) |
4 kV
|
Utilization category |
AC-15
|
Construction size (fuse inserts) |
NH00
|
Connection |
Top or bottom
|
Direction of incoming supply |
As required
|
Distance between busbar centers |
60 mm
|
Electrical connection type of main circuit |
Rail connection
|
Mounting position |
Vertical or horizontal
|
Release indication |
Mechanical top-plate indicator
|
Suitable for |
Triple T profile
Combi-base for busbar mounting (12 - 30 mm) x 5/10 mm Combi-base for direct busbar mounting Double T profile |
Rated conditional short-circuit current (Iq) |
50 kA
50 kA at AC (effective) |
Functions |
Uninterrupted operation (Control mode)
Low-voltage h.b.c. switch-fuse unit |
Overvoltage category |
III
|
Frequency rating of contacts |
50 Hz - 60 Hz
|
Degree of protection |
IP30 (operating state)
IP10 (front cover open) IP30 |
Rated operation current (Ie) |
160 A
|
Voltage rating |
400 V AC
|
Distance between rail centers |
60 mm
|
Type |
|
Special features |
|
Model |
Fuse switch disconnector
|
Lifespan, electrical |
150000 operations
|
Lifespan, mechanical |
100000000 operations
|
Terminal capacity (cable) |
9 mm x 0.8 mm (6x) at box terminal
|
Permitted heat loss from fuse links - max |
20 W at 160 A
|
Terminal capacity (copper busbar) |
Max. 20 mm x 8 mm for flat busbar at flange connection
|
Terminal capacity (solid wire) |
2.5 mm² (2x)
2.5 mm² (2x) at box terminal |
Power consumption per phase (rung) |
2 VA (L2/L3)
|
Terminal capacity (stranded cable) |
1.5 mm² - 70 mm² (1x) at box terminal
70 mm² (1x) at flange connection |
Rated operational current |
125 A / 160 A (AC-23B)
160 A (AC-21B) 1 A (230 V AC-15) 160 A (AC-22B) |